  • Page 1 KP-F80 Progressive Scan B/W CCD Camera Operation Guide...
  • Page 2: Table Of Contents

    ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Adjustment 3  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Timing chart 5  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ External view 9  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ External sync 10  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Connect cables ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Optical system 12  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 10. Optional 13  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 11. Notes to users 16  ・・・・・・・・・・・・ Attachment : Spectral sensitivity characteristic 18  KP-F80...
  • Page 3: General

      1. General The Hitachi KP-F80 are a high performance self-contained black and white CCD camera suited for a wide variety of general purpose and specialized applications. The charge coupled device (CCD) imaging element is 1/3-inch size progressive scanning with independent readout of all picture elements (pixels).
  • Page 4 (10 to 60Hz, amplitude: 0.98mm constant, 60 to 200Hz, amplitude: variable) (10 to 200Hz, sweep:1 min., XYZ, 30 min.) 19) Resistance to shock 686m/s (Drop test, once each top, bottom, left and right) 29(W) × 29(H) × 38.5(L)mm 20) Dimensions 21) Mass 55g approx. KP-F80...
  • Page 5: Adjustment

    1/50000s V.TERM FRAME ON DEMAND RESET TRIGGER CONTROL MODE FIXED PARTIAL SHUTTER SCAN TRIGGER TRIGGER (OPTION) HD/VD IN/OUT TERMINATION HIGH 75ohm IN ..External HD/VD Input INPUT IMPEDANCE OUT.. Internal HD/VD Output EXTERNAL HD AND EXTERNAL VD GAIN control KP-F80...
  • Page 6 Vout Vout Vout Vout Vout GND(HD) GND(HD) GND(HD) GND(HD) GND(HD) (GND) HD IN/OUT HD IN/OUT HD IN/OUT HD IN/OUT (HD IN/OUT) VD IN/OUT Trigger Trigger Trigger/VD Trigger (GND) VIDEO2 Trigger B GND(VD) GND(Trig) GND(Trig) GND(Trig) GND(Trig) (GND)     KP-F80...
  • Page 7: Timing Chart

    5 Timing chart KP-F80...
  • Page 8 5 Timing chart KP-F80...
  • Page 9 5 Timing chart KP-F80 Frame on demand function ONE Trigger High: 5V 2us or more. Trigger pulse Low: 0V Integration time 2us approx. 2us approx. Video output V.SYNC Trigger pulse ..Asynchronous Fixed Shutter High: 5V Trigger pulse Integration time Low: 0V (Shutter switch) 2us approx.
  • Page 10 (The image is output by inputting the Trigger at the VD cycle for this period.) It returns to the Trigger mode if Trigger B signal becomes Low. However, after becoming Low Trigger B, the period of 50ms becomes a Trigger signal input prohibition period.     KP-F80...
  • Page 11: External View

    6 External view         Dimensions        KP-F80...
  • Page 12: External Sync

        Approx. 3.1µs  Approx. 0.4ms        HD and VD phase relationship      VD      Set HD and VD fallings edges to the same phase (0 ± 2 µs)   HD          KP-F80...
  • Page 13: Connect Cables

    8. Connect cables Connection of options KP-F80...
  • Page 14: Optical System

    IR cut filter IRC650 Dimensions: 14 x 12 x 1.0t Part code: XMD0006 * The flange focal point shortens by about 0.3mm when IR cutting filter is removed. We will recommend the dummy glass of the optional to be installed. KP-F80...
  • Page 15: Optional

    10. Optional     1)Tripod adaptor TA-F30 (23885AX) 2)12-pin plug HR10A-10P-12S(01) Product code: 23810AX Viewed from this side KP-F80...
  • Page 16 (23862AX) (23857AX) (23873AX) C-102KSM C-102KS C-102KSS (23863AX) (23858AX) (23874AX) Specify assembly or shielded type at time of order. (): Product code We will recommend the camera cable of the shield type when using it in the sphere of CE. KP-F80...
  • Page 17 Attenuation at 4MHz Attenuation at 7MHz Attenuation at 12MHz length 50dB/Km 70dB/Km 90dB/Km 0.05 0.07 0.09 Attenuation due 0.14 0.18 to cable length(dB) 0.25 0.35 0.45 The video bandwidth obtained by the KP-F80 is up to approximately 12.5 MHz.   KP-F80...
  • Page 18: Notes To Users

    Auto electric shutter   In regions using 50 Hz power line frequency , flicker can appear on the monitor screen from light sources such as fluorescent or mercury. In such cases , release the auto electronic shutter.     KP-F80...
  • Page 19 When fine patterns are shot , moire may be displayed.     The CE mark is required when exporting to Europe. Obtain the necessary authorization for the customer’s system. Enclose the camera in a shielded case and use shielded cable.     KP-F80...