(2) DIGITAL I/O : Setting of input / output line
・SELECTOR : Select the line
Command name
Address
Values (Factory setting 1) : 0 "Line1"
・MODE (related to SELECTOR) : Input/output of the line selected at SELECTOR
Command name
Address
Values (Read only)
・SOURCE (related to SELECTOR) : Select output signal selected at SELECTOR *using when MODE is Output
Command name
Address
Values (Factory setting 1) : 0 "Off"
・INVERTER (related to SELECTOR) : Invert the input/output signal selected at SELECTOR
Command name
Address
Values (Factory setting 0) : FALSE (0)
・FORMAT : Format of the input/output signal
Command name
Address
Values (read only)
(3) TIMER CONTROL : Control of timer to adjust flash pulse
・SELECTOR : Select timer
Command name
Address
Values (Factory setting 1) : 0 "Timer1"
・WIDTH (related to SELECTOR) : Set the duration of timer
Command name
Address
Values (Factory setting 0) : 0
・DELAY TIME (related to SELCTOR): Set the delay of timer
Command name
Address
Values (Factory setting 0) : 0 to 4095
: LineSelector (Enumeration / Standard)
: A0040000 h
Setting of 7 pin of DCIN/SYNC connector.
1 "Line2"
Setting of 10 pin of DCIN/SYNC connector.
2 "Line3"
Setting of 9 pin of DCIN/SYNC connector.
: LineMode (Enumeration / Standard)
: A0040008 h
: 0 "Input"
It means selected line is using for input (when MODE is Line1/Line3).
1 "Output"
It means selected line is using for output (when MODE is Line2).
: LineSource (Enumeration / Standard)
: A0040010 h
1 "ExposureActive"
2 "Timer1Active"
3 "CameraVD"
: LineInverter (Boolean / Standard)
: A0040004 h
Input/output signal is not inverted.
TRUE (1)
Input/output signal is inverted.
: LineFormat (Enumeration / Standard)
: A0040014 h
: 2 "TTL"
It means selected line is TTL level signal (when MODE is Line2).
5 "OptoCoupled" It means selected line is Opto-Coupled (when MODE is Line1/Line3).
* Refer to page 37 "Digital output" about details of flash pulse adjustment
: TimerSelector (Enumeration / Standard)
: A0050000 h
Setting of timer 1.
: TimerDurationRaw (Integer / Standard)
: A0050008 h
Timer is stopped at the same time as the end of exposure.
1 to 4096
Set the following range and intervals.
Camera
KP-FD500GV
KP-F500GV
KP-FD202GV/F202GV
KP-FD145GV/F145GV
KP-FD140GV/F140GV
KP-FD83GV/F83GV
KP-FD33GV/F33GV
: TimerDelayRaw (Integer / Standard)
: A0050010 h
Set the following range and intervals.
Camera
Nothing is output.
Flash pulse (strobe) is output.
Adjusted flash pulse is output.
Camera VD signal is output.
Setting range
from 4.78 µs to 19.57 ms
from 2.7 µs to 11.2 ms
from 1.6 µs to 6.55 ms
from 2.04 µs to 8.35 ms
from 2.04 µs to 8.35 ms
from 3.2 µs to 13.1 ms
from 3.2 µs to 13.1 ms
Setting range
Intervals
Approx. 4.78 µs
Approx. 2.7 µs
Approx. 1.6 µs
Approx. 2.04 µs
Approx. 2.04 µs
Approx. 3.2 µs
Approx. 3.2 µs
Intervals