3. Reset control mode
The readout timing can be set arbitrary set by input the trigger signal (readout pulse) different from the exposure beginning
when Fixed shutter mode or ONE trigger mode. Execute following procedure in addition Fixed shutter/ONE trigger settings.
(1) TriggerSelector → "FrameTransferStart"
(2) TriggerMode → "On"
(3) TriggerSource → "Line1" / "Line3" / "Software" ・・・ (*1)
(4) TriggerActivation → "RisingEdge" / "FallingEdge"
(*1) Please note the value of TriggerSource when using reset control function
Available combination of TriggerSource
TriggerSource
(TriggerSelector: FrameStart)
4. VD reset mode
Internal VD is reset when input external VD signal falls and the camera synchronizes to external VD.
Exposure time is setting shutter speed.
(1) TriggerSelector → "VDReset"
(2) TriggerMode → "On"
(3) TriggerSource → "Line1" / "Line3"
(4) TriggerActivation → "FallinEdge" / "RisingEdge"
(TriggerSelector: FrameTransferStrat)
Line1
Line1
×
Line3
Software
TriggerSource
Line3
Software
×