Dhp-L - Danfoss DHP-H Installation And Service Instructions Manual

Danfoss heat pumps installation and service instructions
Table of Contents

Advertisement

2 .3

DHP-L

Delivery check
1. Check that there is no transport damage. The heat pump is
packaged in cardboard.
2. Remove the plastic wrapping and check that the delivery con-
tains the following components.
DHP-L, sizes 4kW - 10kW:
Part no .
Name
Quantity
9680-5796A00
1
Document kit
9674-57902001
1
Transparent book case
9360-47054001
1
Safety valve 9 bar 1/2"
9588-51618001
1
Kimsafe outdoor sensor 200 035
9360-47054005
1
Safety valve 3 bar 1/2"
9674-24735001
1
Expansion and bleed tank without valve
9551-54479001
1
Cardboard packaged top for HP
9360-51759007
1
Compression angle joint 28x28 joint
9674-54168001
1
Pipe insulation IT 9x28
3311-55300001
1
Brine in Cu pipe in TWS packaging
9684-48342001
2
Rubber bellows for 22-32mm hole
9674-54164001
1
Pipe insulation F-54-A D=54x9mm
5211-50730A00
2
Flexible hose R25 L=600
9360-55453A00
1
Filling kit DN 25
9360-52488001
1
Dirt filter with shut-off DN25
9360-51738005
2
Straight connection LK 303 28xR25
9360-51738008
4
Straight compression connection 22 xR20
DHP-L, sizes 12kW - 16kW:
Part no .
Name
Quantity
9680-5796A00
1
Document kit
9674-57902001
1
Transparent book case
9360-47054001
1
Safety valve 9 bar 1/2"
9588-51618001
1
Kimsafe outdoor sensor 200 035
9360-47054005
1
Safety valve 3 bar 1/2"
9674-24735001
1
Expansion and bleed tank without valve
9551-54479001
1
Cardboard packaged top for HP
9360-51759007
1
Compression angle joint 28x28 joint
9674-54168001
1
Pipe insulation IT 9x28
3311-55300001
1
Brine in Cu pipe in TWS packaging
9684-48342001
2
Rubber bellows for 22-32mm hole
9674-54164001
1
Pipe insulation F-54-A D=54x9mm
5211-50730A00
2
Flexible hose R25 L=600
9360-56911A00
1
Filling kit DN 32
9360-52488001
1
Dirt filter with shut-off DN25
9360-51738005
4
Straight connection LK 303 28xR25
9360-51738008
2
Straight compression connection 22 xR20
10
Dimensions and connections
The brine pipes can be connected on either the left or right-hand
sides of the heat pump.
455
596
5
6
Figure 5: DHP-L, Dimensions and connections .
Position Name
1
Heating system supply pipe, 22 Cu: 4-10 kW, 28 Cu: 12-18 kW
2
Heating system return pipe, 22 Cu: 4-10 kW, 28 Cu: 12-18 kW
3
Alternative for brine supply
4
Alternative for brine return
5
Brine supply pipe (Brine out), 28 Cu
6
Brine return pipe (Brine in), 28 Cu
7
Lead-in for incoming power supply and sensors
8
Lead-in for communication cable
VMBMA102
310
110
40±10
1
2
3
4
378
138
218
298
6
5
5
6
7
8