Danfoss DHP-H Installation And Service Instructions Manual page 42

Danfoss heat pumps installation and service instructions
Table of Contents

Advertisement

Menu selection
SHUNTTIME
HOT WATER STOP
Sub menu SERVICE -> MANUAL TEST
Used to manually test and test operate the heat pump's components or signal outputs.
Menu selection
MANUAL TEST
HEATPUMP
BRINEPUMP
CIRC: PUMP
VXV HOT WATER
SHUNT 1
ADD. HEAT 1
ADD. HEAT 2
ADD. HEAT 3 (DHP-A)
(Defrost card)
SHUNT DEFR (DHP-A)
(Defrost card)
FAN L
(Defrost card)
FAN H
(Defrost card)
ADD.HEAT EXT (DHP-A)
(Defrost card)
ALARM
(Expansion card)
SHUNT COOLING
(Expansion card)
SHUNTGROUP
(Expansion card)
COOLING PASSIVE
(Expansion card)
COOLING ACTIVE
(Expansion card)
VXV POOL
(Expansion card)
42
Meaning
Minimum time interval between signals to shunt motor to affect the supply tem-
perature, in seconds. Applies to all connected shunt groups (applies to system D
or VLD).
Stop temperature for hot water during ADD. HEAT operation (applies to system
VL system).
Meaning
Setting options for manual test.
0 = deactivate manual test
1 = activate manual test
2 = activate manual test with option of navigating from the SERVICE menu to
check that the temperatures rise.
0 = stop heat pump, does not stop started brine pump
1 = start heat pump, also starts brine pump.
NOTE! The heat pump cannot be started in the event of an active alarm.
0 = stop brine pump
1 = start brine pump
0 = stop circulation pump
1 = start circulation pump
0 = heating mode for 3-way valve
1 = hot water mode for 3-way valve
- = closes shunt (applies to D-system)
0 = shunt unaffected
+ = opens shunt (applies to D-system)
0 = stop auxiliary heat step 1
1 = start auxiliary heat step 1
0 = stop auxiliary heat step 2
1 = start auxiliary heat step 2
0 = stop auxiliary heat step 2
1 = start auxiliary heat step 3
- = opens flow from the defrost tank
0 = shunt unaffected
+ = closes the flow from the defrost tank
0 = stop fan
1 = start fan with low speed
0 = stop fan
1 = start fan with high speed
0 = 0V on terminal block 283
1 = control voltage 230V on terminal block 283
0 = stop signal on output External alarm
1 = start signal on output External alarm
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
- = shuts shunt
0 = shunt unaffected
+ = opens shunt
0 = stop passive cooling
1 = start passive cooling (brine pump starts and shunt cooling regulates to set
point value)
0 = stop active cooling
1 = start active cooling (brine pump and compressor starts, shunt cooling regu-
lates to set point value)
0 = normal mode for exchange valve
1 = pool mode for exchange valve
VMBMA102
Factory setting
60S (interval: 10S - 99S)
60°C (interval: 50°C -
65°C)
Factory setting
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-