8.3.2. Service by authorised Mutoh technician
Perform periodical inspections according to the table below.
N°
Part number
1
MY-42110
2
MY-80300
3
MY-35380 + ME-80771
4
ME-18280
5
MY-35085 + ME-80385 + ME-60014
6
MY-80627
7
8
9
10
11
12
N°
1
2
1
2
3
4
5
6
7
8
9
10
11
12
Quantity
4 x 0.8 m
1+ 1 m +1
/
/
/
/
/
/
3
4
5
Rockhopper II series printers – Maintenance Manual
Action
4
Replace the dampers.
2
Replace the pumps.
1+4
Replace wiper arm and wipers.
Replace the tubing from the pumps to the waste
bottle
Replace the right spitting box + tube + L
connection
1
Replace the capping station.
/
Apply grease on head up-down cams.
/
Apply grease on Y-motor belt.
/
Apply grease on roller path carriage.
/
Apply grease on capping station camm + gears.
/
Clean the maintenance station area.
/
Remove dust in fan area underneath print
platform.
Month
6
7
X
X
X
X
X
X
X
X
X
260
8
9
10
AP-74065, Rev. 1.2, 27/09/04
11
12
X
X
X
X
X
X
X
X
X
X
X
X