Wiring Diagram - REMEHA Avanta 12v Installation & Service Manual

Avanta range
Table of Contents

Advertisement

X9
X10
X8
X13
X7
X6
X15
X1
X2
4 5 1
3 2
1 2 3 4 5
BK
BL
BR
WH
GY
1 2 3
1 5
X22
X21
Ignition
GCV
X5
X4
X3
X0
X2
X1
GN/YW
X3
X4
X5
1 2 3 4
1 2 3 4
1 2 3
WIRE COLOURS
BK
BLACK
BL
BLUE
BR
BROWN
GN
GREEN
GN/YW
GREEN/YELLOW
GY
GRAY
RD
RED
WH
WHITE
YW
YELLOW
2.9

Wiring diagram

X0
X7
X8
1 2 3
1 2 3 4
1 2 3 4 5 6 7 8
NO.
NC.
BR
COMM.
WH
GN
YW
1 5 4 2
X81
Os
FAN
BOILER COMPONENTS
As
Flow sensor
CP
Circulation pump
GCV
Gas combination valve
HLT
High limit thermostat
Os
Outdoor sensor
Rs
Return sensor
- - - -
Will not be supplied or wired.
fig. 30
Wiring diagram
25
X6
L
N
1
2
BL
BR
GN/YW
X9
X13
4 1
3
RD
BL
WH
WH
S
T
1 2
1 2
X124
X123
As
Rs
Power supply
230V, 50Hz
N
L
X15
6 8
1 10
BK
BK
1 2
X121
T
HLT
1 10
59970LTGBW7H013