4.4

CLEANING THE BURN POT

The burn pot should be kept clean and its ports should not be plugged with combustion residues. Cleaning the burn
port is simple. To do so, you may use the scraper supplied with unit (in the hopper) or release the clip in front of the
burn pot. Then, remove the burn pot by pulling on it.
4.5

CLEANING THE EXHAUST BLOWER HOUSING

The exhaust blower should be removed for inspection and cleaned once a year. To do so, remove all screws around
the access trap . Then, vacuum thoroughly inside the blower housing. Be very careful not to damage the blower
impellers.