5. Module Reset Switch
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying a RED/GREEN error code at its status
indicator LED.
•
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section G.
•
Locate the module reset switch. (SeeFigure 2.7).
•
Set the module reset switch to the RESET position.
• Wait fi ve (5) minutes to allow possible accumulated gas
to clear.
•
Set the module reset switch to ON.
•
Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a fi ve minute
time period. Gas may accumulate in fi rebox. Call a quali-
fi ed service technician.
MODULE RESET SWITCH
Figure 2.7. Module Reset Switch
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the
RC300 remote.
10
Quadra-Fire • QFI30FB-C, QFI35FB-C • 2221-901 Rev. S • 2/15
I. Before Lighting Fireplace
Before operating this fi replace for the fi rst time, have a
qualifi ed technician:
• Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
• Review proper placement of logs, ember material and/
or other decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT oper-
ate fi replace with fi xed glass assembly removed.
This fi replace has an Intellifi re
TM
Plus ignition system.