Quadra-Fire QFI30-C Owner's Manual
Hide thumbs Also See for QFI30-C:
Table of Contents

Advertisement

Models:
QFI30-C
QFI35-C
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
A CO detector shall be installed in the room where the
appliance in installed.
R
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire QFI30-C

  • Page 1 A CO detector shall be installed in the room where the of gas indicated on the rating plate. This appliance in installed. appliance is not convertible for use with other gases, unless a certified kit is used. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 2: Congratulations

    Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes IN CANADA Serial Number Model: XXXXXXXX ALTITUDE: 0-0000 FT. 0000-0000FT. (Modele): MAX. INPUT BTUH: 00,000 00,000 MIN. INPUT BTUH: 00,000 00,000 Serial XXXXXXXX ORIFICE SIZE: #XXXXX #XXXXX (Serie): Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 3: Table Of Contents

    B. Flue Damper........21  = Contains updated information. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 4: Limited Lifetime Warranty

    Limited 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 6: Listing And Code Approvals

    (0-2000 FT) QFI35-C (NG) CANADA 33,250 18,250 (2000-4500 FT) 31,000 15,500 (0-2000 FT) QFI30-C (LP) CANADA 27,500 14,500 (2000-4500 FT) 35,000 17,000 (0-2000 FT) QFI35-C (LP) CANADA 31,000 15,500 (2000-4500 FT) Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 7: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. • Never leave children alone near a hot fireplace, whether operating or cooling down. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 8: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative front. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 9: Control Module Operation

    ™ • An Intellifire Plus ignition system is standard with this appliance. FLAME HI/LOW STATUS NG/LP GAS-TYPE SWITCH INDICATOR LED SELECTOR SWITCH Figure 2.3 Control Module Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 10: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 11: After Appliance Is Lit

    In an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance is Is it normal to see the pilot flame burn turned off. Some optional control systems available with IPI models may allow pilot flame to continually? remain lit. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 12: Maintenance And Service

    (consult with your dealer) • Carefully set fixed glass assembly in place on appliance. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall decorative front. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 13: Maintenance Tasks-Service Technician

    • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. • Replace appliance if firebox has been perforated. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 14 • Verify that there is not a short in flame sense circuit by checking continuity between pilot hood and flame sense rod. Replace pilot as necessary. (IPI only) Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 15: Installer Guide

    SECTION 5.B AND 11.A SURROUND OR FRONT NOT SHOWN SECTION 2.D AND 8.D. HEARTH EXTENSION GAS LINE (SECTION 9) ACCESS THROUGH EXISTING MASONRY OR WOODBURNING FIREPLACE Figure 4.1 Typical System Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 16: Design And Installation Considerations

    DO NOT use this appliance if any part has been under water. Call a qualified technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 17: Fireplace Size Requirements

    The original fireplace may never be returned to solid fuel in this condition. The sidewalls and top structure of the firebox may not be altered with the exception of removable baffles and dampers. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 18 **Unit depth is measured to the back of the surround to give the depth needed for installation. In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B). Figure 5.2 Fireplace Opening Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 19: Mantel And Wall Projections

    Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to section 1.E. Figure 5.4 Mantel Clearances Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 20: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 21: Installation Preparation

    • It is recommended that extra length of gas line be installed within the existing wood burner or masonry fireplace to allow removal of the insert for future servicing needs. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 22: Installing Vent Pipe And Appliance

    VENT PIPE INLET AIR STARTING COLLAR NOTE: TO ACHIEVE OPTIMUM PERFOR- MANCE OF INSERT, MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Figure 8.1 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 23: Placing, Securing And Leveling The Appliance

    RECOMMENDED for optimal fan performance. See Figure 5.1. • Position any excess flexible vent pipe back up into chimney without sagging. Twist and push flex vent together to shorten. Figure 8.3 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 24: Remote Control

    Auxiliary 300 module can only be placed in the control cavity to the right of the control panel. See Figure 8.4. AUXILIARY 300 MODULE Figure 8.4 Location of AUX300 for Remote Control Blower Function - IPI Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 25: Installing Adaptor And Termination Cap

    Over 20/12 to 21/12 ..8.0 Over 10/12 to 11/12 ..3.25 * 3 foot minimum in snow regions Figure 8.5 Minimum Height from Roof to Lowest Discharge Figure 8.6 Opening Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 26 • Depending on the chimney cleanliness, consider using the full length intake so as to lessen the possibility of sense rod contamination and flame rectification issues. Figure 8.7 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 27: Gas Information

    1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 28: Electrical Information

    AUX1 AUX2 MODULATION ASSEMBLY (110V) BATTERY PACK 6V DC ORANGE GREEN ROCKER (PILOT) SWITCH (MAIN) BROWN WALL SWITCH OR REMOTE INSTALL EMC FILTER UNIT GROUND GROUND Figure 10.1 IPI Wiring Diagram Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 29: Optional Accessories Requirements

    TO VALVE BRACKET (GROUND) PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTACLE VARIABLE SPEED CONTROL BLOWERS FUSE WIRE BLOWER TEMPERATURE RECEPTACLE ASSEMBLY SENSOR SWITCH FUSE WIRE ASSEMBLY Figure 10.2 Fan Wiring Diagram Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 30: Fan Wiring With Remote

    PLUG INTO 120V EXISTING OUTLET DC REGULATOR RECEPTICLE BLOWERS AUX 300 MODULE FUSE WIRE TO CONTROL ASSEMBLY MODULE FUSE WIRE ASSEMBLY BLOWER RECEPTICLE Figure 10.3 Wiring Diagram - Fan with RC200/RC300 Remote Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 31: Finishing

    10 IN. MIN. firebox. Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to section 1.E. Figure 11.1 Clearances to Mantels or other Combustibles above Appliance Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 32: Appliance Setup

    • Place lava rock in front of and to the sides of the burner. Figure 12.2 Placement of Embers PLACE LAVA ROCK IN SHADED AREA ONLY Figure 12.1 Placement of Lava Rock Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 33: Install The Log Assembly

    Figure 4. Bend the refractory tab down as shown in Figure 5. Repeat this step for the right refractory panel. Figure 5. Bend Refractory Tab Figure 4. Install Side Refractory Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 34 Rotate the back end of the log clockwise until it contacts the right refractory panel. LOG GROOVE LOG PIN (FOR LOG #6) MATES WITH SLOT MATE NOTCH NOTCH WITH GRATE BAR Figure 10. Log #4 Figure 11. Log #4 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 35 Log #6 (SRV2227-704): Rest the left end of Log #6 on the burner. Mate the notch on the left end of log with the grate bar. The log should rest on both log grooves as illustrated in Figure 9 and Figure 10. 2227-935B Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 36 Install the left side refractory as shown in Figure 3. Bend the refractory tab down as shown in Figure 4. Repeat this step for the right refractory panel. REFRACTORY Figure 3. Install Side Refractory Figure 4. Bend Refractory Tab Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 37 Log #4 SRV(2225-705): Mate the slot on the bottom of Log #4 with the right log pin. Refer to Figure 11 for location of log slot. Rotate the right end of the log clockwise until the groove on the end of the log mates with the grate bar. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 38 Log #7 SRV2225-704): Note the location of the groove on the underside of the log. Place the opposite end on the flat spot on Log #3. See Figure 9. Mate the groove on the underside of the log with the grate bar as shown in Figure 15, centered between the andirons. 2225-935C Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 39: Fixed Glass Assembly

    Verify top latches are fully engaged and then fasten the two bottom latches. QFI30-C 3/8 in. 1/2 in. QFI35-C 3/8 in. 1/2 in. Figure 12.3 Fixed Glass Assembly Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 40: Troubleshooting

    D. Pilot valve solenoid Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 41 Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 42: Reference Materials

    1-3/4 1-3/4 10-5/8 9-1/2 4-11/16 4-5/8 *Note: Location G on Figure 14.1 is measuring the appliance depth, for installation depth reference Location G on Figure 5.2. Figure 14.1 Appliance Dimensions Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 43 AF-QFI30, AF-QFI35 DECORATIVE FRONTS 13-1/2 4-5/8 23-11/16 23-3/16 AF-QFI30 4-5/8 25-11/16 25-3/16 AF-QFI35 FSP-QFI30, FSP-QFI35 DECORATIVE FRONTS 11-5/8 5-1/2 23-11/16 23-3/16 FSP-QFI30 29-1/4 16-1/16 4-15/16 25-11/16 25-3/16 FSP-QFI35 Figure 14.2 Decorative Front Dimensions Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 44 TP-QFI30/TP-QFI35 DECORATIVE FRONTS 32-15/16 12-9/16 4-5/8 23-1/2 TP-QFI30 15-9/16 4-11/16 38-1/16 26-1/2 TP-QFI35 Figure 14.3 Decorative Front Dimensions Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 45: Vent Kits Components

    46DVA-GK to connect collinear flex vent to SL-D vent pipe to extend the run. FLEX3-30: One 3 inch flexible liner expands to 30 feet. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 46: Service Parts

    Rheostat Knob 2205-129 Control Panel 2206-800 Rheostat Blower GFK-210-C Wire Assembly 2206-068 Cord Assembly 2201-017 Qty 2 req 2206-085 Fuse Wire Assembly Additional service part numbers appear on following page. 2/16 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 47: Service Parts

    2205-129 On/Off Rheostat 2206-800 Blower Assembly GFK-210-C Power Cord Assembly 2206-068 2201-017 Cord Assembly Fuse Wire Assembly Qty 2 req 2206-085 Additional service part numbers appear on following page. 2/16 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 48 Thermostat Assembly 046-018A **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 1A fuse, 3/4" long Additional service part numbers appear on following page. Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 49 Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 QFI35-C Conversion Kit NG NGK-I35-C Conversion Kit LP LPK-I35-C Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...
  • Page 50: Contact Information

    This product may be covered by one or more of the following patents: (United States) 5613487, 5647340, 5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2016 Quadra-Fire • QFI30-C, QFI35-C • 2227-901 Rev. S • 2/16...

This manual is also suitable for:

Qfi35-c

Table of Contents