Quadra-Fire QFI30FB-IFT Homeowner And Installation Manual

Quadra-Fire QFI30FB-IFT Homeowner And Installation Manual

Hide thumbs Also See for QFI30FB-IFT:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation Manual
Installation and Appliance Setup
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire QFI30FB-IFT

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 2: Table Of Contents

    Wiring ........19  = Contains updated information. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2555-982 5/18 Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 4: Product Specific And Important Safety Information

    38,000 19,000 (0-2000 FT)) (Propane) known to the State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 5: Getting Started

    Reciprocating saw Manometer Flat blade screwdriver Noncorrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 6: Framing And Clearances

    *Dimensions H, O, F and I are measured to the surround brackets. Note: Location N on Figure 4.1 is measuring the appliance depth, for installation depth reference Location O. See also Figure 4.2. Figure 3.1 Appliance Dimensions Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 7 MISSION FULL VIEW DECORATIVE FRONTS 17-3/4 2-9/16 36-3/4 25-3/4 25-1/4 MFV-FBQF30-XX 19-7/8 2-9/16 38-3/4 27-3/4 27-1/4 MFV-FBQF35-XX Figure 3.2 Decorative Front Dimensions - Firescreen and Mission Full View Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 8 FORGED ARCH DECORATIVE FRONTS 29-3/4 17-7/16 3-1/2 37-1/8 25-3/8 24-5/8 FA-FB30-BK 29-3/4 20-1/16 3-1/4 38-1/2 27-3/4 FA-FB35-BK Figure 3.3 Decorative Front Dimensions - Forged Arch Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 9: Fireplace Size Requirements

    RECOMMENDED - 1/4 IN. REQUIRED QFI30FB-IFT 11-1/4 QFI35FB-IFT METAL FLOOR OF EXISTING FACTORY-BUILT FIREBOX 5 IN. 6 IN. THIS SECTION OF 12 IN. METAL FLOOR HAS BEEN REMOVED Figure 4.1-A Figure 4.1-B Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 10 **Unit depth is measured to the back of the surround to give the depth needed for installation. In addition to these dimensions, also reference Clearances and Mantel Projections (Section 10.A) Figure 4.2 Fireplace Opening Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 11: Termination Location And Vent Information

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 5.1 Minimum Height From Roof To Lowest Discharge Opening Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 12: Installation Preparation

    • It is recommended that extra length of gas line be installed within the existing wood burner or masonry fireplace to allow removal of the insert for future servicing needs. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 13: Installing Vent Pipe And Appliance

    INLET AIR VENT PIPE NOTE: TO ACHIEVE OPTIMUM PERFORMANCE, INLET AIR STARTING COLLAR MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Figure 7.1 Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 14: Connecting Vent Pipe

    • Trim chimney top plate to minimize excess overhang or bend over flue tile (see Figure 7.2). • Place 3/8 in. bead of 300 ºF silicone on flue tile top. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 15: Placing, Securing And Leveling The Appliance

    WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Figure 7.3 Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 16: Installing Adaptor And Termination Cap

    Over 20/12 to 21/12 ..........8.0 * H minimum may vary depending on regional snowfall. Refer to local codes. Figure 7.4 Minimum Height from Roof to Lowest Discharge Opening Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 17 • Depending on the chimney cleanliness, consider using the full length intake so as to lessen the possibility of sense rod contamination and flame rectification issues. Figure 7.5 Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 18: Electrical Information

    If interference is occurring on the same circuit, the use of surge protectors may help alleviate the interference. NOTICE: DO NOT wire 110-120 VAC to wall switch. RECOMMENDED ELECTRICAL OUTLET LOCATIONS APPLIANCE Figure 8.1 Electrical Outlet Detail Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 19: Wiring

    2166-302 (NG) 6 PIN 2166-303 (LP) FAN 110-120 VAC GFK-210-C LIGHT WIRE 2550-301 ASSEMBLY 2532-017 BATTERY PACK 2326-134 HALOGEN BULBS (X 2) 2201-150 Figure 8.2 IntelliFire™ Touch Wiring Diagram Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 20 105 °C rated wire. PLUG INTO 120V EXISTING OUTLET BLOWERS FUSE WIRE ASSEMBLY FUSE WIRE ASSEMBLY NOTE: SEE FIGURE 8.2 FOR ADDITIONAL INFORMATION Figure 8.3 Fan Wiring Diagram Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 21: Gas Information

    4500 feet (1370 m). • If substituting for these components, please consult local codes for compliance. Check with your local gas utility to determine proper orifice size. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 22: Air Shutter Setting

    NOTICE: If sooting occurs, provide more air by opening the air shutter. AIR SHUTTER Figure 9.1 Air Shutter Air Shutter Settings Propane QFI30FB-IFT 1/4 in. Full Open QFI35FB-IFT 1/4 in. Full Open Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 23: Finishing

    For non-combustible material specifications refer to section 1.E. Figure 10.2 Alternate Minimum Non-Combustible Board Coverage Requirement EXISTING NON-COMBUSTIBLE FACING 12 IN. MAX. 12 IN. MIN. Figure 10.1 Mantel Clearance Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 24: Appliance Setup

    • Note that the extended glass latch tabs on the glass frame are for the bottom glass latches. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 25: Remove The Shipping Materials

    WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 26: Place The Lava Rock

    PLACE LAVA ROCK IN GRAY AREA ONLY Figure 11.6 Placement of Lava Rock Figure 11.7 Placement of Embers (QFI30FB-IFT) EMBERS NOT ALLOWED IN PILOT AREA Figure 11.8 Placement of Embers (QFI35FB-IFT) Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 27: Install The Log Assembly

    Log #2 (SRV2221-701): Position Log #2 as shown in Figure 5. See Figure 2 and Figure 6 for additional points of reference. The recessed area on the bottom of the log and the back right corner of the burner top mate. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 28 Log #5 on the flat spot indicated in Figure 7. Locate right end of log against the grate and to the left of the log pin. Ensure the nose of the log does not cover any burner ports. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 29 Log #7 on the flat spot indicated in Figure 11. Place the back end of Log #7 on the left side of the knot. See Figure 13. 2221-935D Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 30 Slide the log back until it rest against the back of the log support. The left end of the log should touch Log #1. Swing the right end of the log counterclockwise until it contacts the right refractory wall. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 31 Log #6 (SRV2223-705): Position Log #6 as shown in Figure 11. See Figures 2, 5 and 10 for additional reference points. Place the front and back ends of the log on the flat spots as shown in Figure 11. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 32 Log #7 (SRV2221-707): Position Log #7 as shown in Figure 12. See Figure 2 and 10 for additional reference points. Place the front and back ends of the log on the flat spots as shown in Figure 12. 2223-935D Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 33: Intellifireā„¢ Touch Control System Setup

    If this occurs, restart the appliance. NOTICE! Open windows for air circulation during fire- place break-in. • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 34: Heat Management

    NOTICE! Set the fan speed to high on the RC400 remote control during the first three to four hours of break-in operation. See Section G. This break-in will ensure optimum speed control of the fans during subsequent use. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 35: Reference Materials

    Figure 12.2 Direct Vent Flex Liner Accessory Kits FLEX3-30: One 3 in. flexible liner expands to 30 feet. FLEX-CNCT: Connector kit - 3 in. liner to 3 in. liner, one connector per kit. Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...
  • Page 36: Accessories

    Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer, please visit www.quadrafire.com. Printed in U.S.A. - Copyright 2018 Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18...

This manual is also suitable for:

Qfi35fb-ift

Table of Contents