Quadra-Fire REMINGTON QFP40 Operation Manual
Quadra-Fire REMINGTON QFP40 Operation Manual

Quadra-Fire REMINGTON QFP40 Operation Manual

Direct vent gas fireplace

Advertisement

INSTALLATION, VENTING, OPERATION AND MAINTENANCE MANUAL
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
If the information in these instructions is not followed exactly a fire or explosion may
result causing property damage, personal injury or death.
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
N Extinquish any open flame.
N Open windows.
N Do not try to light any appliance.
N Do not touch any electric switch.
N Do not use any telephone in your build-
ing.
This appliance may be installed in an aftermarket permanently located, manufactured
(mobile) home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases, unless a certified kit is used.
1445 North HIghway
Colville, WA 99114
REMINGTON QFP40
Direct Vent Gas Fireplace
WARNING!
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
SAVE THESE INSTRUCTIONS
Part #250-4721 (842-3291) 06/2001
N Immediately call your gas supplier from a
neighbor's phone.
N Follow the gas supplier's instructions.
N If you cannot reach your gas supplier, call
the fire department.
www.aladdinhearth.com
aladdin@aladdinhearth.com

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire REMINGTON QFP40

  • Page 1 REMINGTON QFP40 Direct Vent Gas Fireplace INSTALLATION, VENTING, OPERATION AND MAINTENANCE MANUAL Installation and service must be performed by a qualified installer, service agency, or the gas supplier. WARNING! If the information in these instructions is not followed exactly a fire or explosion may result causing property damage, personal injury or death.
  • Page 2 Ask your Quadra-Fire Dealer for information on these options. From design, to fabrication, to shipping: Our guarantee of quality is more than a word, it’s Quadra- Fire tradition, and we proudly back this tradition with a Lifetime Warranty.
  • Page 3 REMINGTON QFP40 Direct Vent FIREPLACE NOTES MODEL NAME Quadra Fire REMINGTON QFP40 SERIAL NUMBER Located on front, lower ledge of control panel. DATE PURCHASED DEALERSHIP WHERE PURCHASED DEALER PHONE ADDITIONAL INFORMATION After completing your warranty card, attach your sales receipt and warranty stub here for future reference.
  • Page 4: Table Of Contents

    REMINGTON QFP40 Direct Vent FIREPLACE CONTENTS SAFETY & CLEARANCES: Ratings Plate ....................6 Standards Listing & Clearances Label ............7 Safety Notices ....................9 SPECIFICATIONS: Heating Specifications .................. 10 ZC Appliance Dimensions ................10 Minimum Cabinet Dimensions ..............11 INSTALLATION PREPARATION: Installation Terminology ................
  • Page 5 REMINGTON QFP40 Direct Vent FIREPLACE CONTENTS COMPLETING INSTALLATION: Gas Line Requirements ................46 Electrical Connection ................... 47 Optional Thermostat Connection ..............47 Optional Brick Installation................48 Logset and Nugget Installation ..............50 Glass Installation ..................53 Fascia Installation ..................53 Leak Test ......................
  • Page 6: Ratings Plate

    REMINGTON QFP40 Direct Vent FIREPLACE RATINGS PLATE MODEL: REMINGTON SERIAL NO. SERIAL NO. MODEL: REMINGTON 1445 N. Highway 061-S-14-5 Colville, WA 99114 APPROVED FOR CANADA AND USA TO: ANSI Z21.88-1998/CSA 2.33-M1998 Vented Gas Fireplace Heaters and applicable sections of UL307b Gas Burning Heating Appliances for Mobile Homes and recreational vehicles, CAN/CGA 2.17-M91...
  • Page 7: Standards Listing & Clearances Label

    NOT FOR USE WITH SOLID FUEL - NOT FOR USE WITH AIR FILTERS The “Remington QFP40” is factory equipped for natural gas (NG) and is field convertible to pro- pane gas (LP), when equipped with the Conversion Kit #842-4470 available from an Aladdin Hearth Products dealer.
  • Page 8 REMINGTON QFP40 Direct Vent FIREPLACE WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational pro- cedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
  • Page 9: Safety Notices

    REMINGTON QFP40 Direct Vent FIREPLACE SAFETY NOTICES IF YOU SMELL GAS! ☛ Do not light any appliance ☛ Extinguish any open flame ☛ Do not touch any electrical switch or plug or unplug anything ☛ Open windows and vacate building ☛...
  • Page 10: Heating Specifications

    REMINGTON QFP40 Direct Vent FIREPLACE HEATING SPECIFICATIONS Natural Gas Propane BTU Input 27,000 - 40,000 32,000 - 40,000 BTU Output on “HI” (with Fan - without Fan) 34,400 34,400 Efficiency** (with Fan) **Efficiency rating is the thermal efficiency rating of the product determined under con- tinuous operation, and independent of an installed system at maximum horizontal vent- ing (30').
  • Page 11: Minimum Cabinet Dimensions

    REMINGTON QFP40 Direct Vent FIREPLACE MINIMUM CABINET DIMENSIONS The following minimum cabinet dimensions are the minimal allowances for clearance to combustibles, as referenced on page 7 of this manual. See page 21 for additional mantel information. Maximum mantel depth is 12"...
  • Page 12: Installation Terminology

    REMINGTON QFP40 Direct Vent FIREPLACE INSTALLATION TERMINOLOGY Simpson-DuraVent Venting Framing Horizontal Termination Cap Mantel Combustible Wall (See Clearances, Page 7) DuraRock, Tile, etc. Fascia Stand- Appliance offs Glass Access Door Electrical line Gas line Page 12 250-4721 JUNE 2001...
  • Page 13: Preparation

    REMINGTON QFP40 Direct Vent FIREPLACE PREPARATION ✔ Failure to follow all of the required installation procedures may result in property damage, bodily injury or even death. ✔ This appliance must be installed in accordance with all local codes, if any;...
  • Page 14: Lp Conversion Instructions

    REMINGTON QFP40 Direct Vent FIREPLACE LP CONVERSION INSTRUCTIONS Part # 842-4470 is required for this procedure. NOTE: If converting this unit to propane, do so at this point of installation. WARNING ! The installation of this conversion kit must only be undertaken by a quali- fied and certified gas appliance installer.
  • Page 15 REMINGTON QFP40 Direct Vent FIREPLACE CONVERSION INSTRUCTIONS, (CONT.) Burner Orifice Replacement If logset is installed, remove logs and embers at this time. Use a Phillips screwdriver to remove pilot lighting channel and front log rack. Remove the two Phillips head screws that secure the front and rear burner pans in place.
  • Page 16: Minimum Framing Dimensions

    REMINGTON QFP40 Direct Vent FIREPLACE MINIMUM FRAMING DIMENSIONS ❖ The 1/2" stand-offs on the back and sides and 4" stand-offs on the top of the fireplace separate the fireplace from the framing members (see page 12, Installation Terminology). These stand-offs may contact the framing mem- bers but no material may be placed between the stand-offs and the framing.
  • Page 17: Corner Installations

    REMINGTON QFP40 Direct Vent FIREPLACE CORNER INSTALLATIONS The usual 45º installation uses the minimum framing dimensions shown in the illustration below. PLEASE NOTE: All clearances as referenced on page 7 still apply. 13 13/16" 12 1/16" 19 5/8" 45 3/16"...
  • Page 18: Raised Fireplaces

    REMINGTON QFP40 Direct Vent FIREPLACE RAISED FIREPLACE The fireplace and it’s hearth, if desired, may be placed on a platform designed to support the fireplace weight (240lbs.) and venting. Hearth Raised Platform Page 18 250-4721 JUNE 2001...
  • Page 19 REMINGTON QFP40 Direct Vent FIREPLACE RAISED FIREPLACE WITH RAISED HEARTH Raised Hearth Raised Platform Page 19 250-4721 JUNE 2001...
  • Page 20: Hearth Requirements

    REMINGTON QFP40 Direct Vent FIREPLACE HEARTH REQUIREMENTS No clearances to combustible flooring are required for installation of the Remington QFP40, as referenced in the Clearances to Combustibles on page 7 of this manual. NOTE: Ensure the depth of your flooring material does not exceed the 1" height at bottom front flange of the ZC Appliance, illustrated below.
  • Page 21: Mantel Requirements

    REMINGTON QFP40 Direct Vent FIREPLACE MANTEL REQUIREMENTS COMBUSTIBLE MANTELS As referenced on page 7, Clearance to Combustible Materials: The allowable height from the top of the glass to the lower edge of a maximum mantel depth of 12", is 30 1/2".
  • Page 22: Arched Fascia Dimensions

    REMINGTON QFP40 Direct Vent FIREPLACE FASCIA DIMENSIONS ARCHED Part #841-0710 Gold Part #841-0750 Brushed Nickel Part #841-0720 Black 40 1/2" R53 7/16" 31" 32 13/16" 17 1/2" 28 7/8" 7 3/16" ACID WASH ALERT! An acid wash (muriatic acid) is commonly used to remove excess mortar, primarily on brick faces.
  • Page 23: Rectangular Fascia Dimensions

    REMINGTON QFP40 Direct Vent FIREPLACE FASCIA DIMENSIONS RECTANGULAR Part #841-0730 Black 40 3/4" 31" 31 1/2" 17 1/2" 7 3/8" Page 23 250-4721 JUNE 2001...
  • Page 24: Facing Requirements

    REMINGTON QFP40 Direct Vent FIREPLACE FACING REQUIREMENTS Durarock or other non-combustible material must extend from header to floor and to framing on either side. HEADER NON- COMBUSTIBLE FACING 3" MIN. FOR ARCHED or RECTANGULAR FASCIA NOTE: Tile may be tucked beneath the fascia on sides and top, but not on the bottom.
  • Page 25: Facing Over 1" Thick

    REMINGTON QFP40 Direct Vent FIREPLACE FACING OVER 1” (25mm) THICK Facing material greater than 1" (25mm) thick, such as brick, river rock, etc., will require installation around the perimeter of the face. If your unit did not ship with a template for this purpose, contact your dealer for an Arched Fascia Template, Part #842-3770.
  • Page 26: General Venting Instructions

    INSTALLATION PRECAUTIONS The Quadra-Fire Remington QFP40 Fireplace is an engineered product that has been designed and tested. The warranty will be voided, and serious fire, health, or other safety hazards may...
  • Page 27: Simpson Dura-Vent Parts List & Kits

    Snorkel terminations are available for applications which may require a vertical rise on the building exterior. The follow- ing components have been approved for use with the Quadra-Fire Remington QFP40 Fire- place.
  • Page 28: Venting Installation Options & Guidelines

    REMINGTON QFP40 Direct Vent FIREPLACE VENTING INSTALLATION OPTIONS & GUIDELINES There are four types of direct vent system installations approved for use with the REMINGTON QFP40. It is very important to maintain a balance between the combustion air intake and the flue gas exhaust venting system.
  • Page 29: Horizontal

    REMINGTON QFP40 Direct Vent FIREPLACE TERMINATION CAP REQUIREMENTS: ON HORIZONTAL TERMINATIONS USE ONLY DURAVENT PART # 985, OR ALADDIN HEARTH PRODUCTS PART #HHW2 VERTICAL TERMINATIONS USE ONLY DURAVENT PART #991. FIG. 1 HORIZONTAL TERMINATION Pipe Length Horizontal 90° Elbow Termination...
  • Page 30: Class A Metal Chimney

    REMINGTON QFP40 Direct Vent FIREPLACE VENTING INSTALLATION, CONT. FIG. 3 INSTALLATION INTO A CLASS A METAL CHIMNEY (USA ONLY) Dura Vent #991 ONLY High Wind Termination Cap Top Adapter Existing Metal Chimney System 4" Flex Pipe Retro Connector Direct Vent Pipe...
  • Page 31: Masonry Chimney

    REMINGTON QFP40 Direct Vent FIREPLACE VENTING INSTALLATION, CONT. FIG. 4 INSTALLATION INTO A MASONRY CHIMNEY (USA ONLY) DuraVent #991 High Wind Termination Cap ONLY Top Adapter Flashing 4" Flex Liner Retro Connector Direct Vent Pipe Page 31 250-4721 JUNE 2001...
  • Page 32: How To Use Vent Graph

    REMINGTON QFP40 Direct Vent FIREPLACE HOW TO USE VENT GRAPH 1. Measure the distance from the top of stove to the center of the 90° elbow. On the graph below, draw a horizontal line from that measurement on the vertical axis across until it intersects with the slanted line.
  • Page 33: Horizontal Termination Requirements

    REMINGTON QFP40 Direct Vent FIREPLACE HORIZONTAL TERMINATION REQUIREMENTS A. *12” (30cm) minimum: Clearance above grade, veranda, porch, deck, or balcony. B. *12” (30cm) minimum: Clearance to window or door that may be opened. C. 12” (30cm) minimum: Clearance to permanently closed window (recommended to prevent condensation on window.
  • Page 34: Horizontal Installation Instructions

    REMINGTON QFP40 Direct Vent FIREPLACE HORIZONTAL INSTALLATION NOTE: Horizontal sections require a 1/4" (6mm) rise for every 12" (305mm) of horizontal travel. Exterior Vent Diameter = 6 5/8" (177mm); Inner Vent Diameter = 4" (101mm) Horizontal sections require noncombustible support every 3' (914mm) , e.g. plumbing tape.
  • Page 35 REMINGTON QFP40 Direct Vent FIREPLACE Step 3. With the adapter, any vertical pipe required for your installation, and the 90° elbow attached to the flue outlet, measure the distance from the base of the ZC appliance to the center of the 90° elbow, adding 1/4" rise for every 1' of horizontal venting, as referenced in Note 1, below.
  • Page 36 REMINGTON QFP40 Direct Vent FIREPLACE HORIZONTAL INSTALLATION (CONT.) Step 4. Position the horizontal vent termination in the center of the 10" (254mm) square hole, run a bead of non-hardening mastic around its outside edges, so as to make a seal between it and the wall, attach termination cap to the exterior wall with the four wood screws provided.
  • Page 37 REMINGTON QFP40 Direct Vent FIREPLACE HORIZONTAL INSTALLATION (CONT.) Step 5. Slide the stove and vent assembly (see Fig. 9 below) towards the wall, carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extend into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1¼"...
  • Page 38: Vertical Installation Instructions

    REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS USING GS SERIES PIPE Step 1. Check the installation instructions for required 1" clearances (air space) to com- bustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 40, Fig. 16. Do not pack air space with insulation.
  • Page 39 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS Step 3. To install the round support box/wall thimble in a flat ceiling, cut a 10" (254mm) square hole in the ceiling, centered on the hole drilled in Step 2. Frame the hole as shown in Figure 13.
  • Page 40 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS (CONT.) USING GS SERIES PIPE ( CONT Step 7. Continue to assemble pipe sections until the height of the vent cap (H) (Figure 15) meets the minimum code requirements described in code requirements as outlined in the current CAN/CGA-Bl49 Installation Codes (in Canada), the Na- tional Fuel Gas Code NFPA 54/ANSI Z223.1 (in USA), or local codes.
  • Page 41 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS (CONT.) CATHEDRAL CEILING INSTALLATION Step 1. Follow installation Steps 1 and 2 under vertical termination section. Step 2. Using the plumb-bob, mark the centerline of the venting system on the ceiling, and drill a small hole through the ceiling and roof at this point. From the roof, locate the drill hole and mark the outline of the cathedral ceiling support box.
  • Page 42 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS (CONT.) INSTALLATION INTO A CLASS A METAL CHIMNEY (USA ONLY) NOTE: Have the existing installation inspected by a qualified chimney sweep or profes- sional installer prior to converting to direct vent. The existing chimney system must be in serviceable condition and functionally sound and clean.
  • Page 43 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS (CONT.) INSTALLATION INTO AN EXISTING MASONRY CHIMNEY (USA ONLY) Step 1. Before cutting any holes, assemble the desired sections of direct vent pipe to determine the center of the masonry penetration. FIG. 22 Step 2.
  • Page 44 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS (CONT.) Step 5. Connect the flex liner to the top adapter FIG. 24 using three sheet metal screws (see Fig- ure 19, page 42). Step 6. Feed the flex liner through the flashing into the chimney.
  • Page 45 REMINGTON QFP40 Direct Vent FIREPLACE VERTICAL INSTALLATION INSTRUCTIONS (CONT.) Step 9. Attach the flex to the retro connector. FIG. 26 Use three sheet metal screws to attach the flex liner to the connector (Figure 26). Mount the retro connector to the ma- sonry wall using masonry bolts.
  • Page 46: Gas Line Requirements

    REMINGTON QFP40 Direct Vent FIREPLACE GAS LINE REQUIREMENTS ✔ The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the requirements listed below. Ensure that a 1 1/4" allowance from base of unit is made for hard pipe installation, see page 16, Minimum Framing Dimen- sions.
  • Page 47: Electrical Connection

    REMINGTON QFP40 Direct Vent FIREPLACE ELECTRICAL CONNECTION Make sure the household breaker is shut off prior to working on any electrical lines. This appliance, when installed, must be electrically grounded in acordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
  • Page 48: Optional Brick Installation

    REMINGTON QFP40 Direct Vent FIREPLACE BRICK INSTALLATION Installation of the brick set should be made prior to the logset, nugget and lava rock installation. Optional Accessory Part # 841-0740 Kits includes: 1 Rear brick, 1 Right Brick, 1 Left Brick and 2 Brick clips.
  • Page 49 REMINGTON QFP40 Direct Vent FIREPLACE BRICK INSTALLATION, CONT. FIG. 3 3. Attach brick retaining clips to right and left sides, using mounting screws removed in Step 2. (Fig. 4). Mounting screw & clip placement. FIG. 4 Page 49 250-4721 JUNE 2001...
  • Page 50: Logset And Nugget Installation

    REMINGTON QFP40 Direct Vent FIREPLACE LOGSET AND NUGGET INSTALLATION NOTE: If you plan to install the optional brick set, do so prior to installing the logset, nuggets and lava rock. Continue at this point AFTER installing the optional brick set.
  • Page 51 REMINGTON QFP40 Direct Vent FIREPLACE LOGSET AND NUGGET INSTALLATION, CONT. FIG. 2 NUGGET PLACEMENT 3. Set Rear Log in rear log bracket with pegs in upright position. Fig. 3. 4. Set the notch in the Front Log over the pilot transfer channel and center log side-to-side on the grate with pegs in upright position.
  • Page 52 REMINGTON QFP40 Direct Vent FIREPLACE LOGSET AND NUGGET INSTALLATION, CONT. 5. Place Left Twig onto pegs on top of Rear FIG. 7 LOWER FRONT LEFT TWIG and Front Logs. Fig. 5. 6. Place Right Twig onto pegs on top of Rear and Front Logs.
  • Page 53: Glass Installation

    REMINGTON QFP40 Direct Vent FIREPLACE INSTALLING GLASS The glass assembly has a narrow metal edge at top of the frame, and wide metal edge at bottom of the frame. To install the glass assembly, lift and set the bottom T-bar extensions onto the bottom alignment pins located at the edge of firebox--refer to diagram below.
  • Page 54: Leak Test

    REMINGTON QFP40 Direct Vent FIREPLACE LEAK TEST Turn on gas to the fireplace. Turn on gas at the manual shutoff valve. Leak test all gas joints prior to starting the appliance. Familiarize yourself with the control panel components, see page 58.
  • Page 55: Lighting Instructions

    REMINGTON QFP40 Direct Vent FIREPLACE LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly B.
  • Page 56: Shutter Adjustment

    REMINGTON QFP40 Direct Vent FIREPLACE SHUTTER ADJUSTMENT A 5/32 Allen wrench is supplied with unit to make adjustment to the two Allen bolts which operate the shutter adjustment for rear (top) and front (lower) main burners. These are located beneath the firebox, behind the control panel on your left at the base of the burner pans.
  • Page 57: High Altitude Operation & Adjustment

    REMINGTON QFP40 Direct Vent FIREPLACE HIGH ALTITUDE OPERATION In Canada, this unit is approved from 0 to 4500 feet above sea level. Installation of this stove at altitudes above 4500 feet is subject to field test of the individual installation and approval by the local authority having jurisdiction.
  • Page 58: Operation

    REMINGTON QFP40 Direct Vent FIREPLACE OPERATION Read this entire manual prior to using the fireplace. Pay particular attention to the “Safety Precautions” section on pages 6-9. Failure to follow the instructions may result in prop- erty damage, bodily injury, or even death.
  • Page 59: Maintenance

    REMINGTON QFP40 Direct Vent FIREPLACE MAINTENANCE GENERAL Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera.
  • Page 60: Yearly Servicing

    REMINGTON QFP40 Direct Vent FIREPLACE YEARLY SERVICING PROCEDURES WARNING! Failure to inspect and maintain the fireplace may lead to improper com- bustion and apotentially dangerous situation. The following procedures are rec- ommended to be completed by a qualified technician once per year, preferably prior to the burning season.
  • Page 61: Glass Replacement

    REMINGTON QFP40 Direct Vent FIREPLACE GLASS REPLACEMENT Replace glass with part #842-3820 ONLY, available from your dealer. Turn valve to “OFF” position to prevent start-up of unit while door is removed. Prepare a flat area to lay the door on by covering the surface with cardboard, disposable tarp or paper large enough to contain the entire door.
  • Page 62: Blower Replacement

    REMINGTON QFP40 Direct Vent FIREPLACE BLOWER REPLACEMENT Part #842-3790 Disconnect power to unit at power supply (this may require shutting off power at the circuit breaker box). Remove fascia and door. Remove control panel cover. Disconnect white wire from white wire at junction box in unit.
  • Page 63: Electrical Schematic

    REMINGTON QFP40 Direct Vent FIREPLACE ELECTRICAL SCHEMATIC Page 63 250-4721 JUNE 2001...
  • Page 64: Troubleshooting

    REMINGTON QFP40 Direct Vent FIREPLACE TROUBLESHOOTING Pilot won’t light ✔ Is a gas shut-off valve turned on? ✔ Is the valve control knob turned to “PILOT” (See Lighting Instructions, #7, Pg. 55). ✔ Is the valve control knob pushed in? (See Lighting Instructions, #8) ✔...
  • Page 65 REMINGTON QFP40 Direct Vent FIREPLACE TROUBLESHOOTING, (CONT.) Pilot Goes Out Once a Month or More ✔ Has the gas supply been shut off? (Keep gas supply turned on) Flames Are Too blue ✔ Has the fireplace just been started? (This is normal - see Initial Start-up Pg. 54).
  • Page 66: Parts & Accessories

    REMINGTON QFP40 Direct Vent FIREPLACE PARTS & ACCESSORIES PARTS 842-0240 Valve (NG) 842-3501 Pilot 842-3910 Pilot Orifice NG (.025) 842-3900 Pilot Orifice LP (.016) 842-4480 Logset (7 pieces) 842-4490 Rear Log 842-4520 Front Log 842-4500 Left Twig 842-4510 Right Twig...
  • Page 67: Warranty

    Aladdin Hearth Products. This new Quadra-Fire product must be installed by a competent, authorized service contractor. It must be installed and operated at all times in accordance with the Installation, Operation and Maintenance Instructions included in this manual, as well as any applicable local and national codes.
  • Page 68 REMINGTON QFP40 Direct Vent Gas Fireplace Owner’s Manual...