Quadra-Fire QV32B-A Owner's Manual

Quadra-Fire QV32B-A Owner's Manual

Installation and operation
Hide thumbs Also See for QV32B-A:
Table of Contents

Advertisement

Models:
QV32B-A
QV36B-A
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
R
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire QV32B-A

  • Page 1 Technologies suggests NFI certifi ed or factory trained CAN/CSA Z240MH. professionals, or technicians supervised by an NFI This appliance is only for use with the type(s) of gas indicated certifi ed professional. on the rating plate. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 2 INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 3: Table Of Contents

    K. Install Decorative Wall Components (SLP only) ..37 L. Heat Shield Requirements for Horizontal Termination . . . 37 M. Install Horizontal Termination Cap (DVP and SLP Pipe) . 38 = Contains updated information. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 4: Listing And Code Approvals

    fi bers, plastics, or other material that can ig- nite and burn, whether fl ame proofed or not, or whether plastered or unplastered shall be considered combustible materials. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 6: Getting Started

    Plumb line Safety glasses Level 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Manometer Voltmeter Tape measure Noncorrosive leak check solution One 1/4 inch female connection (for optional fan). Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 7: Framing And Clearances

    1511 1117 1734 1231 1746 D for Alcove Installation 45-1/2 64-3/8 45-1/2 64-3/8 16-1/4 48-1/2 68-3/4 16-5/8 7-1/2 QV36B-A 1155 1067 1635 1321 1861 1231 1746 Figure 3.1 Appliance Locations Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 8: Constructing The Appliance Chase

    (Depth) 8-5/8 38-1/4 28-1/4 16-1/4 Inches QV36B-A 1067 Millimeters 8-5/8 34-3/4 28-1/4 16-1/4 Inches QV32B-A Millimeters * Dimension when rear venting with one 90º elbow Figure 3.2 Clearances to Combustibles Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 9: Mantel Projections

    MATERIAL 5-3/8 IN. MINIMUM UNLIMITED Note: Clearance from opening to perpendicular wall. 1/2 in. Figure 3.6 Wall Projection (Acceptable on one side of opening.) NON-COMBUSTIBLE ZONE Figure 3.4 Non-Combustible Zone Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 10: Termination Locations

    6 in. 20 in. min. Horizontal distance between terminations 20 in. 24 in. min. Distance to perpendicular wall 18 in. 18 in. Vertical distance between terminations Figure 4.3 Multiple Vertical Termination Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 11 Figure 4.4 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 12: Vent Information And Diagrams

    45º elbows (see DVP12MI 3 to 12 76 to 305 Figure 5.1). DVP24MI 3 to 24 76 to 610 Figure 5.2 DVP Pipe Effective Length Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 13 However, the vent at- C L E A R A N C E tachment point and the fi restop loca- tion are considered to be supports. Figure 5.3 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 14: Vent Diagrams

    Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3). Figure 5.4 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 15 Note: There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3). INSTALLED HORIZONTALLY Figure 5.5 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 16 Note: There MUST be a 25% Note: Use SLP Series reduction in total H when components only. using fl ex vent except when using the simple up and out installation (see Figure 5.3). Figure 5.6 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 17 fl ame height. If the vent confi guration has a total vertical of 15-60 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 18 Note: There MUST be a 25% Note: Use SLP Series reduction in total H when components only. using fl ex vent except when using the simple up and out installation (see Figure 5.3). Figure 5.9 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 19 Note: Use SLP Series reduction in total H when components only. using fl ex vent except when using the simple up and out installation (see Figure 5.3). INSTALLED HORIZONTALLY Figure 5.10 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 20 Note: There MUST be a 25% Note: Use SLP Series reduction in total H when using components only. fl ex vent except when using the simple up and out installation (see Figure 5.3). Figure 5.11 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 21 1.5 m 7 ft. 2.1 m 14 ft. 4.3 m MAX. = 7 ft. (2.1 m) MAX. = 14 ft. (4.3 m) MAX. = 40 ft. (12.2 m) Figure 5.13 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 22 2 ft. 610 mm 5-1/2 ft. 1.7 m 3 ft. 914 mm 7-1/2 ft. 2.3 m MAX. = 7-1/2 ft. (2.3 m) MAX. = 40 ft. (12.2 m) Figure 5.15 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 23 14-1/2 ft. 4.4 m MAX. = 7-1/2 ft. (2.3 m) MAX. = 14-1/2 ft. (4.4 m) MAX. = 40 ft. (12.2 m) Note: Use DVP Series components only. Figure 5.17 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 24: Vent Clearances And Framing

    * When using SLP pipe, minimum clearances from the vent pipe to combustible materi- als at wall shield firestops are: Top: 2-1/2 in. (64 mm) Bottom: 1/2 in. (13 mm) Sides: 1 in. (25 mm) Figure 6.1 Horizontal Venting Clearances To Combustible Materials Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 25: Wall Penetration Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 6.3 Exterior Wall Hole Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 26: Vertical Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 6.4 Installing the Attic Shield Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 27: Install Attic Insulation Shield

    • Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 28: Appliance Preparation

    Figure 7.2 Rotate the top heat shield to the vertical position as shown above. The heat shield must remain in Figure 7.5 Remove the insulation basket and white insula- the vertical position. tion from the center vent pipe. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 29: Rear Vent

    Figure 7.8 Fold the tabs toward the center of the fi re plug up against the appliance and over the tabs. Use two self- (90°) and remove the insulation gasket. tapping screws to secure gasket to outer wrap. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 30: Securing And Leveling The Appliance

    • Do NOT notch into the framing around the appliance spacers. Failure to keep insulation, framing or other material away from the appliance may cause fi re. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 31: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 8.4 Seams Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 32: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not Figure 8.5 Adding Venting Components required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 33: Secure The Vent Sections

    DO NOT allow vent to sag below connection point to appliance. Figure 8.10 Rotate Seams for Disassembly Figure 8.11 Align and Disassemble Vent Sections Figure 8.8 Securing Vertical Pipe Sections Figure 8.9 Securing Horizontal Pipe Sections Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 34: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. WARNING! Risk of Fire! Clean out ALL materials from Figure 8.13 inside the support box and complete the vertical vent run and termination. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 35: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 8.15. Figure 8.17 Assembling the Storm Collar Around the Pipe Figure 8.17 Assembling the Storm Collar Around the Pipe Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 36: Install Rf4-8

    fl ashing. SHINGLES TRIMMED FLASHING OVER SHINGLES OVER SHINGLES FLASHING Figure 8.22 Installation Complete Figure 8.19 Trim Rubber Boot Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 37: Install Vertical Termination Cap

    Once the pipe section and the termination cap have been • connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 8.24. Figure 8.24 Wall Thimble Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 38: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 39: Gas Information

    Natural Gas Propane 5.0 inches 11.0 inches Minimum inlet pressure w.c. w.c. 14.0 inches 14.0 inches Maximum inlet gas pressure w.c. w.c. 3.5 inches 10.0 inches Manifold pressure w.c. w.c. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 40 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 41: Electrical Information

    • Incorrect wiring will override IPI safety lockout and may cause explosion. STANDING PILOT REMOTE SWITCH PIGTAIL ON/OFF VALVE SWITCH OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE Figure 10.2 Standing Pilot Ignition Wiring Diagram Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 42: Junction Box Installation

    Figure 10.4 Junction Box Wired to Wall Switch connector (1/4 inch male) as shown. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 43: Finishing

    Note: Clearance from opening to perpendicular wall. Figure 11.4 Wall Projection (Acceptable on one side of opening.) 1/2 in. SHEETROCK 3-1/2 in. OR COMBUSTIBLE MATERIAL 1/2 in. NON-COMBUSTIBLE ZONE Figure 11.2 Non-Combustible Zone Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 44: Facing Material

    0 IN. HIGH TEMPERATURE (300º F / 149º C MIN.) TOP & SIDE SEAL JOINT BOTTOM 1 INCH MAY BE COVERED WITH COMBUSTIBLE OR NON-COMBUSTIBLE MATERIAL. Figure 11.5 Facing Material Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 45: Appliance Setup

    EMBER MATERIAL Figure 12.1 Placement of Embers • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 46: Positioning The Logs

    STEP 5: LOG #4 (SRV780-707): Place log #4 across log STEP 6: LOG #5 (SRV2014-704): Place log #5 on log #1 #3 and resting on log #1. and log #2 with burned area facing burner. 2014-925B 6/03 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 47 STEP 5: LOG #4 (SRV780-707): Place log #4 across log #1 STEP 6: LOG #5 (SRV700-706): Place log #5 across logs and log #2 with burned out area facing out. #1 and #3 with the Y-shape facing out. 2016-925B 6/03 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 48: Glass Assembly

    QV32B-A 1/16 in. 3/8 in. QV36B-A 1/16 in. 3/8 in. LATCHES (BOTH BOTTOM AND TOP) GLASS ASSEMBLY Figure 12.14 Glass Assembly Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 49: Operating Instructions

    • Glass door MUST be in place and sealed before operating appliance. • Only use glass door certifi ed for use with appliance. • Glass replacement should be done by qualifi ed technician. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 50: Lighting Appliance

    OFF”. Do not force. instructions accompanying appliance. Close control access panel. 464-903G For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 51: After Appliance Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when continually? ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 52: Troubleshooting

    With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 53 Ensure that the glass is tightened properly on the unit, particularly on top corners. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 54: Maintaining And Servicing Appliance

    • Restricted air fl ow affects burner operation. Clean: • Glass • Air passageways, grilles, control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 55: Maintenance Tasks

    1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 56: Reference Materials

    3-9/16 6-7/8 6-7/8 23-3/8 26-7/8 34-3/8 37-7/8 35-1/2 39-15/16 1015 8-13/16 8-13/16 16-5/16 16-5/16 25-3/4 30-3/4 12-7/8 15-3/8 15-7/8 15-7/8 6-5/8 6-5/8 2-3/16 2-3/16 30-1/16 33-9/16 Figure 16.1 Appliance Dimensions Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 57: Vent Components Diagrams

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 58 117 mm 12 in. 5-3/8 in. 9-3/8 in. Effective Trap2 (305 mm) 137 mm 238 mm Length DVP-TRAP Horizontal Termination Cap DVP-TRAP1 DVP-TRAPK1 DVP-TRAP2 DVP-TRAPK2 Figure 16.3 DVP vent components Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 59 7-1/4 in. (184 mm) DVP-TB1 12-1/2 in. Basement Vent Cap (318 mm) 5-1/4 in. (133 mm) DVP-HSM-B DVP-TVHW Extended Heat Shield Vertical Termination Cap (Highwind) Figure 16.4 DVP vent components Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 60 2 - 12 51 - 305 SLP-FLEX-2 SLP-FLEX-3 SLP-FLEX-5 1524 SLP-FLEX-10 3048 SLP-HVS RF4-8 SLP-FS SLP-WS Horizontal Pipe Roof Flashing Ceiling Firestop Wall Shield Firestop Support Figure 16.5 SLP Series Vent Components Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 61 Termination Cap 26 in. 660 mm DVP-HSM-B SL-2DVP DVP-2SL Extended Heat Shield Adapter Adapter SLP-DCF-BK SLP-WT-BK Ceiling Firestop Wall Thimble-Black Black SLP-FLEX-TRAP Horizontal Termination Kit Figure 16.6 SLP Series Vent Components Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 62: Service Parts List

    QV32B-A C. Service Parts List Service Parts Diagram Beginning Manufacturing Date: June 2003 Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 63: Service Parts List

    Post 0021080519 230-1520 Pre 0021080519 446-505 Pilot Orifi ce NG Post 0021080519 2103-116 Pre 0021080519 446-517 Pilot Orifi ce LP Post 0021080519 2103-117 Additional service part numbers appear on following page. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 64: Log Set Assembly

    Service Parts List QV36B-A Service Parts Diagram Beginning Manufacturing Date: June 2003 Ending Manufacturing Date:______ Log Set Assembly Part number list on following page. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 65 Post 0021076968 230-1520 Pre 0021076968 446-505 Pilot Orifi ce NG Post 0021076968 2103-116 Pre 0021076968 446-517 Pilot Orifi ce LP Post 0021076968 2103-117 Additional service part numbers appear on following page. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 66 QV32B-A, QV36B-A Service Parts Valve Assembly Parts List Beginning Manufacturing Date: June 2003 Ending Manufacturing Date: ______ Standing Pilot Valve Assembly Part number list on following page. Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 67 Post 0021080519 2025-101/2044-155 Shutter Backet Assembly 2026-017 Shutter Sleeve 2026-130 Jumper Wire 049-552A Gasket Assembly Includes: Burner Neck, Shutter Bracket, Vent, Seal 2115-080 Cap, Cover, Valve Plate and Air Passage Gaskets Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 68: Limited Lifetime Warranty

    This limited Lifetime Warranty is effective on all appliances sold after May 1, 2002 and supersedes any and all warranties currently in existence. 250-8620 Rev K Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...
  • Page 69: Contact Information

    6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2008 Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. J • 7/08...

This manual is also suitable for:

Qv36b-a

Table of Contents