Get Live List
GET_LIVE_LIST: Command Number = 0018h
This command returns 127 bytes of information about the nodes on the network. Every byte
stands for one bus subscriber, and the position of the byte in the response data assigns the address
Command and response layout:
Message ID
Message Information
Command Number
Data Size
Extended Word 1
Extended Word 2
Extended Word 3
Extended Word 4
Extended Word 5
Extended Word 6
Extended Word 7
Extended Word 8
• Station Type [0 ...126]
00h:
Slave Station
01h:
Master Station not yet ready for Token ring (station only physically at the bus)
02h:
Master Station ready to enter Token ring (there is not yet any Token transmission)
03h:
Master Station in Token ring (Token transmission through the station)
04h:
Station does not exist
• Fault Information
If 'Invalid Other 'is returned in the Message Information word in the header of the response,
information about the fault can be found here.
000Ah:
Failed to build Live List
00FFh:
Module not initialized
110
Command
(ID)
4002h
0018h
0000h
-
-
-
-
-
-
-
-
Response data byte 1
Response data byte 2
:::
Response data byte 127
Response
(ID)
0002h
0018h
007Fh
-
-
-
-
-
-
Return Code
Fault Information
Station Type 0
Station Type 1
:::
Station Type 126