Performance Data Sheet - Watts Premier DELUXE PLUS Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

5 SV Deluxe, CRO-TFM-5SV, Ultra 5 and Pur-Tek, Watts 25, Watts RO-4, Watts RO-5, RO-TFM-4SV, RO-TFM-5SV
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is micro biologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. Operating Temperature:
3. Operating Water Pressure:
4. pH
5. Maximum iron present in incoming feed water supply must be less than 0.2 ppm.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Sediment Pre-filter:
Carbon Pre-filter:
Final Carbon filter
R.O. Membrane:
* All Prices Subject to change without notice
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 58. This
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
Avg. In.
(mg/L)
Arsenic (Pentavalent)
334.62 ug/L
Barium Reduction
Cadmium Reduction
0.031
Chromium (Hexavalent)
Chromium (Trivalent)
Copper Reduction
Cysts
222,077#/ml
Fluoride Reduction
Lead Reduction
Perchlorate
0.10
Radium 226/228
25pCi/L
Selenium
TDS
Turbidity
81 NTU
Recovery - 16.2%
Depending on water chemistry, water temperature, and water pressure Watts Premier's R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage
tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER'S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.
Phone: (623) 931-1977
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
California Certification # 00-1452
System conforms to NSF Standard 58 for specific claims.
Maximum: 100°F (40.5°C)
Maximum: 100 psi (7.0kg/cm2)
2 to 11
#5m-10
#5MCB
#1m-6/#1M-10
#TFM-24
Avg. Eff.
% Reduction pH
(mg/L)
5.039 ug/L
98.4%
10.2
0.13
98.7%
0.0001
99.7%
0.30
0.006
98.0%
0.30
0.003
99.0%
3.0
0.04
98.7%
10 #/ml
99.99%
8.0
0.33
95.9%
0.15
0.004
97.3%
0.003
96.5%
5pCi/L
80.0%
0.10
<0.001
99.0%
760
85
88.0%
0.15 NTU
99.8%
Fax: (623) 931-0191
Watts Premier Inc.
Change time Frame
6 Months
6 Months
12 Months
2 to 5 years
Pressure
Max Eff.
50psi
19 ug/L
7.24
50psi
7.49
50psi
0.0009
7.24
50psi
7.24
50psi
7.64
50psi
50psi
7.49
50psi
7.49
50psi
7.39
50 psi
0.005 mg/L
7.24
50psi
5pCi/L
50psi
<0.001
5.94
50psi
50psi
0.28 NTU
Daily Production Rate - 9.56 GPD
Page 20
Minimum: 40° (4.4°)
Minimum: 40 psi (2.8kg/cm2)
Cost
$ 3.50
$10.50
$6.75 / $9.50
$64.95
Inf. challenge
mg/L
concentration
mg/L
0.30±10%
0.27
10.0±10%
0.03±10%
0.013
0.03±10%
0.008
0.03±10%
0.06
3.0±10%
58
minimum 50,000/mL
0.47
8.0±10%
0.008
0.15±10%
0.10±10%
25pCiL±10%
0.10±10%
100
750±40mg/L
11±1 NTU
Efficiency - 9.58%
Email: wpmail@watts.com
Max Allowable
concentration
mg/L
0.010 mg/L
2.0
0005
0.1
0.1
1.3
N/A
1.5
0.0107
0.006
5pCiL
0.05
187
0.5 NTU