Watts Premier Filter Pure UF3 Installation, Operation And Maintenance Manual

Watts Premier Filter Pure UF3 Installation, Operation And Maintenance Manual

3-stage filtration system

Advertisement

Quick Links

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Save manual for future reference
3-Stage Filtration System
Model: Filter Pure UF3
WARNING
!
Please read carefully before proceeding with
installation. Your failure to follow any attached
instructions or operating parameters may lead to the
product's failure.
Keep this Manual for future reference.
WARNING
!
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system.
IMPORTANT
If you are unsure about installing your WATTS water filter, contact
a WATTS representative or consult a professional plumber.
CAUTION
!
Discard small parts remaining after the installation.
NOTICE
Failure to install the system correctly voids the warranty.
Handle all components of the system with care. Do not drop,
drag or turn components upside down.
Be sure the floor under the water filter system is clean, level
and strong enough to support the unit.
System Tested and certified by WQA
against NSF/ANSI Standards 42 and 53
for the reduction of the claims specified
on the performance Data sheet.
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier
www.premierh2o.com
199494
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
Page 1
USA: Tel. (800) 752-5582
Canada: Tel. (905) 332-4090
Manual Edition: 04/20/2017

Advertisement

Table of Contents
loading

Summary of Contents for Watts Premier Filter Pure UF3

  • Page 1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference 3-Stage Filtration System Model: Filter Pure UF3 WARNING Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure.
  • Page 2: Overview

    Overview Thank you for your purchase of a state of the art Water Treatment system. Your new Filter-Pure UF3 system is equipped with a unique swivel valve in head push button assembly. This allows for a simple and sanitary push button filter change that does not require you to turn off the water source to the filtration system.
  • Page 3: Table Of Contents

    Table of Contents Overview ..................................2 System Maintenance ............................... 2 Operational Parameters ..............................4 Contents of Under Counter System ..........................4 Tools Recommended For Installation ..........................4 Using Quick-Connect Fittings ............................5 System Diagram ................................5 Drill a Hole for the Faucet in a Porcelain Sink ........................6 Or Punch a Hole for the Faucet in a Stainless Steel Sink ....................
  • Page 4: Operational Parameters

    0.5 gpm @ 60 psi Contents of Under Counter System Please make sure all of the items listed below are contained in the box. If any of the items are missing please contact Watts Premier at 800-752-5582 prior to installing. ‰ UF3 Unit ‰...
  • Page 5: Using Quick-Connect Fittings

    Using Quick-Connect Fittings Cutting Connecting Make certain to push the tubing completely into the con- nector until it comes into contact with the internal tubing stop. The collet (gripper) has stainless steel teeth which hold the tube firmly in position while the O-ring provides a Cut the tube square.
  • Page 6: Drill A Hole For The Faucet In A Porcelain Sink

    Drill a Hole for the Faucet in a Porcelain Sink For Marble Counter-tops, we recommend contacting a qualified contractor for drilling a hole in a NOTICE marble counter-top. Note: Most sinks are predrilled with 1½” or 1¼” diameter hole that you can use for your Drinking Water faucet. (If you are already using it for a sprayer or soap dispenser, see Step 1).
  • Page 7: Faucet Installation

    Faucet Installation Parts List for Faucet Item Description Escutcheon Plate Black Rubber Washer Black Locating Washer (use where A 1/2” hole is available, reverse when mounting on stain- less steel or when using drilled hole) Lock Washer Insert Plastic Sleeve 1/4”...
  • Page 8: Adapt-A-Valve Installation

    Adapt-a-Valve Installation Water supply line to the system must be from the cold water supply line only. Hot water will NOTICE severely damage your system. Do not use Teflon tape with the Adapt-A-Valve™. NOTICE Faucet Line Faucet Connection Faucet Line Faucet Connection Line from...
  • Page 9: Mounting System Under Sink

    Mounting System Under Sink Step 16: Locate an area best fitted for mounting the system. Allow approximately 2” (5cm) clearance between the bottom of the filter housing and the floor of the sink cabinet. Step 16: Using the mounting holes on the bracket, mark the location for the mounting screws on the cabinet wall under the sink.
  • Page 10: Start Up Instructions

    Changing the Filter Cartridges Your system is equipped with valved heads which will automatically turn off the water supply to each filter when the fil- ter is released, thus you do not need to turn off the incoming water supply at the Adapt-a-Valve. The faucet must be off when filters are replaced.
  • Page 11: Performance Data Sheet

    Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 8538 Model: Filter Pure UF3 GENERAL USE CONDITIONS: 1. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
  • Page 12: Performance Data Sheet

    Influent Challenge Maximum Permissible Percent Substance Concentration Product Water Reduction (mg/L unless noted) Concentration DINOSES 0.17 0.0002 EDB (see ETHYLENE DIBROMIDE)* >99% 0.044 0.00002 ENDRIMN 0.053 0.0059 ENTAMOEBA (See CYST) 99.99% minimum 50,000/mL 99.95% ETHYLBENZENE* >99% 0.088 0.001 ETHYLENE DIBROMIDE (EDB)* >99% 0.044 0.00002...
  • Page 13: Service Record

    Service Record Date of Purchase: _______________ Model Number: _______________ Serial Number: _______________ Date of Install: _________________ Installed by: __________________ Sediment Carbon Sediment Carbon Filter Block Membrane Filter Block Membrane Date (6 Months) (6 Months) (12 Months) Date: (6 Months) (6 Months) (12 Months) Page 13...
  • Page 14: Limited Warranty

    If any part of your UF3 is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Watts Premier will repair or, at Watts Premier’s option, replace the system at no charge.