Adapt-A-Valve Installation; Drain Saddle Installation - Watts Premier DELUXE PLUS Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

Adapt-a-Valve Installation - Part# 134007
Configuration for 3/8"
compression fittings
Step 11
Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
Step 12 Attach the adapt-a-valve as illustrated in the three photos above, choosing the configuration
that fits your plumbing. (When attaching the adapt-a-valve to straight pipe threads, use Teflon
tape on the threads without the rubber washer.)
Caution: Water supply line to the system must be from the cold water supply line only.
Hot water will severely damage your system.
Drain Saddle Installation - Part# 164016
Drain Saddle fits standard 1 ¼" – 1 ½" drain pipes
Caution:
If you have a garbage disposal, do not install the drain saddle near it.
Installation of the drain saddle must be either above the garbage disposal, or
if a second sink drain is available, install it above the cross bar on the second
drain. Installation of the drain saddle near a garbage disposal may cause
the drain line to plug. If no other installation of drain line is available, Watts
Premier offers drain line installation kit (part number 164020) that can be used
with garbage disposals.
Step 13
Gather the pieces of the drain saddle
1 Black compression nut
2 Screws
2 Nuts for screws
The small square black foam gasket with a circle cut out of the middle
Step 14
must be applied to the inside of the drain saddle. Remove sticky tape
backing and stick to the drain saddle as shown.
The drain saddle must be mounted at least 1 ½" above the nut of the
Step 15
P-trap or cross bar from the garbage disposal to insure proper drainage.
Assemble the drain saddle around the drain pipe at the best available
location. Using Phillips screw driver tighten screws evenly and securely
on both sides of the drain saddle. Keep the plastic compression nut off
at this time.
Caution: Do not over tighten the screws. It may crack the drain saddle.
Hot
Cold
Supply
Supply
1 Semicircle bracket with opening
1 Foam gasket
1 Semicircle bracket
Page 8
Configuration for 1/2"
compression fittings

Advertisement