Performance Data Sheet - Watts Premier HT-5-VOC-B Installation, Operation And Maintenance Manual

Reverse osmosis system
Table of Contents

Advertisement

TECHNICAL & WARRANTY INFORMATION
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. Do not use
with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst
reduction may be used on disinfected water that may contain filterable cysts.
2. Operating Temperature:
3. Operating Water Pressure:
4. pH
5. Hardness of more than 10 grains per gallon (170 ppm) may reduce TFM membrane life expectancy.
6. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Depending on incoming feed water conditions replacement time frame may vary.
Change Time
6 months:
12 months
3 to 5 years
This system has been tested according to NSF/ANSI 58 for reduction of the substances below. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in
NSF/ANSI 58. This system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate)
at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to
be used on water supplies containing a detectable free chlorine residual at the system inlet or on water supplies that have been demonstrated to
contain only pentavalent arsenic. Treatment with chloramine (combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic
to pentavalent arsenic. Please see the Arsenic Facts section of the installation manual for further information.
Avg. In.
(mg/L)
Arsenic (Pentavalent)
334.62 ug/L
Barium Reduction
Cadmium Reduction
Chromium (Hexavalent)
Chromium (Trivalent)
Copper Reduction
Cysts
222,077#/ml
Fluoride Reduction
Lead Reduction
Radium 226/228
25pCi/L
Selenium
TDS
Turbidity
81 NTU
*Refer to the VOC Performance Data Sheet for the complete list of VOC's.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under operating
conditions that approximate typical daily usage.
is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed.
There is an average of 4 gallons of reject water for every 1 gallon of product water produced. Testing performed under standard laboratory conditions,
actual performance may vary. Refer to owners manual for further maintenance requirements and warranty information.
Phone: (480) 675-7995

Performance Data Sheet

HT-5-VOC-B
8716 W Ludlow Drive Suite #1
(480) 675-7995 wpmail@wattsind.com
Maximum: 100°F (40.5°C)
Maximum: 100 psi (7.0kg/cm2)
2 to 11
Description
Sediment Pre-filter (104017) Carbon Pre-filter (101009)
VOC Carbon Block (101013) Final Carbon filter (100010)
R.O. Membrane (110009)
Avg. Eff.
% Reduction pH
(mg/L)
5.039 ug/L
10.2
0.13
0.031
0.0001
0.30
0.006
0.30
0.003
3.0
0.04
10 #/ml
99.99%
8.0
0.33
0.15
0.004
5pCi/L
0.10
<0.001
765
24
0.15 NTU
RECOVERY - 16.75%
Recovery rating means the percentage of the influent water to the membrane portion of the system that
Fax: (623) 866-5666
Watts Premier Inc.
Peoria, AZ 85381
Pressure
98.4%
50psi
98.7%
7.24
50psi
99.7%
7.49
50psi
98.0%
7.24
50psi
99.0%
7.24
50psi
98.7%
7.64
50psi
50psi
95.9%
7.49
50psi
97.3%
7.49
50psi
80.0%
7.24
50psi
99.0%
50psi
96%
7.84
50psi
99.8%
50psi
GALLONS - 24.8 GPD
Page 15
Minimum: 40° (4.4°)
Minimum: 40 psi (2.8kg/cm2)
Max Eff.
Inf. challenge
mg/L
concentration
mg/L
19 ug/L
0.30±10%
0.27
10.0±10%
0.0009
0.03±10%
0.013
0.03±10%
0.008
0.03±10%
0.06
3.0±10%
58
minimum 50,000/mL
0.47
8.0±10%
0.008
0.15±10%
5pCi/L
25pCiL±10%
<0.001
0.10±10%
39.0
750±40mg/L
0.28 NTU
11±1 NTU
EFFICIENCY - 12.0%
Email: wpmail@watts.com
Max Allowable
concentration
mg/L
0.010 mg/L
2.0
0005
0.1
0.1
1.3
N/A
1.5
0.0107
5pCiL
0.05
187
0.5 NTU

Advertisement

Table of Contents
loading

Table of Contents