Panasonic KX-TD816CE Installation Manual page 27

Digital super hybrid system
Hide thumbs Also See for KX-TD816CE:
Table of Contents

Advertisement

3
Features
Note:
• The UCD Time Table is not available for incoming extensions or transferred calls.
• If the overflow extension or Time Table number is not assigned, the system does not answer the call and
waits for any extension to be idle. In this case, IRNA will be employed.
• If the system sends the OGM after queuing, the OGM answering time is subject to the time assigned in
program [213] "DISA Delayed Answer Time."
• Dialing is disregarded during an OGM.
• In sequence assignment, "Sx" can be assigned in a space other than the first only when another "Sx" is
assigned in the first space.
• In sequence assignment, an assignment after "TR," "RT" or "Blank" is not available.
• An OGM is only available for KX-TD1232.
• If a timer is the first item in a Time Table sequence, it will delay answering according to the Timer's
time setting. The caller will hear a ringback tone.
• Music on Hold after an OGM can be changed to a ringback tone by program [990] "System Additional
Information, Field (1)."
Conditions
Programming References
• UCD can be used in the following cases:
a) The floating number of UCD is assigned as the DIL 1:1 destination.
b) The floating number of UCD is assigned as the Intercept Routing
destination.
c) The floating number of UCD is dialed from an extension.
d) The floating number of UCD is dialed from DISA.
e) The floating number of UCD is assigned as the UCD Overflow
destination.
f) The floating number of UCD is assigned as the Direct Dialing In
destination.
• This feature requires assignment of a UCD group in System
Programming. An extension cannot belong to two or more UCD
groups.
• The floating number can be assigned on a UCD group basis. The UCD
group is based on the extension group.
• It is possible to set the log-in or log-out status on an extension basis.
A UCD call can arrive at an extension in log-in status within the UCD
group, but cannot arrive at extensions in log-out status. If the extension
would like to leave the group temporarily, the extension sets the log-out
status by the feature number to prevent UCD calls being sent to their
extensions. When the extension re-joins the group, the extension sets
the log-in status.
• There should be at least one extension that is in log-in status.
Section 4, System Programming — in this manual
[106] Station Hunting Type
[126] UCD Overflow
[127] UCD Time Table
[611] ISDN DDI Number / Floating Number Transformation
[813] Floating Number Assignment
U
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-td1232ce

Table of Contents