Download Print this page

Insinger Ensign 40-2 Technical Manual page 10

Counter type dishwasher
Hide thumbs Also See for Ensign 40-2:

Advertisement

Initial Start-Up Adjustments
Tank Overfill Adjustment
1. Locate tank overfill timer in the control panel.
See the control panel layout drawing located in
Section 4, Electrical Schematic and Replacement
Parts.
2. The overfill timer starts timing when the upper
level float is actuated. Adjust the overfill timer
potentiometer to turn the tank fill solenoid off
when the water level is 1/4" below the lip of the
overflow tube.
3. The timer has a built in dwell timing delay of 5
seconds (nominal to dampen float bounce caused
by tank water motion).
Final Rinse Pressure Adjustment
1. The final rinse pressure must be adjusted to
20PSI. This is done by adjusting the pressure
regulator.
Ensign_40-2_TM2009
®
8
PART 2 INSTALLATION INSTRUCTIONS
www.insingermachine.com
800-344-4802

Advertisement

loading