Alarm attributes

9.5 Interface alarms

Refer to Section
9.2 Introducing the alarm attributes.
crocusIfConv<2m/Nx64><Tt/Cv>/<dteInterface>/alarmInfo
The different alarms related to the <dteInterface> object together with their explanation and their default
alarmMask and alarmLevel value are given in the following table:
The alarm ...
linkDown
(for RS530, V35,
V36I)
linkDown
(for X21)
linkDown
(for Bridge)
linkDown
(for Router)
132
is generated ...
when no RTS signal is detected. I.e. the connection
between the Crocus CNV and the DTE is down.
The linkDown alarm is only generated if the attribute
rtsControl is set to external. If the attribute rtsControl is
set to internal, the linkDown alarm will never be
generated.
when no valid C signal is detected. I.e. the
connection between the Crocus CNV and the DTE
is down.
when there is no connection with the LAN. I.e. the
LAN is not connected or no valid LAN signals are
present.
when there is no connection between the router
and the Crocus CNV. Because this connection is
made by the interface connector, it is highly unlikely
that this alarm will be generated. However, when it
does occur it might indicate that the router interface
is faulty.
for the general alarm attributes.
Crocus CNV
Default value
alarmMask
alarmLevel
enabled
3
enabled
3
enabled
3
enabled
3
Reference manual

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Crocus CNV and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents