OneAccess Crocus CNV User And Reference Manual page 129

Table of Contents

Advertisement

Crocus CNV
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/Test Activation
Use this action to perform a test on the Crocus CNV. These tests are useful to trace possible problems.
Possible tests are: no, al, dl, rdl, et, alEt, rdlEt.
To execute a test, proceed as follows:
Step
In the TMA window, select the object g703OnBoard and the group Performance.
1
2
In the action window of TMA, click the left mouse button on the field under the heading
Argument Value.
⇒ A drop down box appears.
3
In the drop down box, select the test you want to execute.
4
Press the right mouse button and select Execute.
For more information on these tests, refer to Chapter
Reference manual
Action
11.5 - Diagnostic
tests.