Crocus CNV
Status attributes
crocusIfConv<2m/Nx64><Tt/Cv>/flash1Version
This displays the code and version of the firmware currently stored in flash bank 1. If this value is empty
then flash bank 1 does not contain firmware.
Example: Txxxx/xxxxx 01/01/00 12:00. In this example the following parameters are visible:
• Txxxx is the firmware code for this device
• /xxxxx is the firmware version
• 01/01/00 is the firmware release date
• 12:00 is the firmware release time.
crocusIfConv<2m/Nx64><Tt/Cv>/flash2Version
This displays the code and version of the firmware currently stored in flash bank 2. If this value is empty
then flash bank 2 does not contain firmware or the Crocus CNV is equipped with one flash bank only.
crocusIfConv<2m/Nx64><Tt/Cv>/activeFlash
This displays which flash bank is currently active.
crocusIfConv<2m/Nx64><Tt/Cv>/bootVersion
This displays the code and version of the boot software currently used in the Crocus CNV.
Example: Txxxx/xxxxx 01/01/00 12:00. In this example the following parameters are visible:
• Txxxx is the boot software code for this device
• /xxxxx is the boot software version
• 01/01/00 is the boot software release date
• 12:00 is the boot software release time.
crocusIfConv<2m/Nx64><Tt/Cv>/flashVersion
This attribute indicates how many flash banks are present in the Crocus CNV. Hence it indicates how
many firmware versions can be stored in the Crocus CNV. The possible values are 1 and 2.
Reference manual