OneAccess Crocus CNV User And Reference Manual page 113

Table of Contents

Advertisement

Crocus CNV
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/ifSpeed
This attribute displays the current interface speed in bits per second (bps), e.g. 640000. When the
interface is down (ifOperStatus = down), the interface speed is 0.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/ifOperStatus
This attribute displays the current operational status of the interface. The possible indications are:
Value
up
The interface is up, data transfer is possible. In other words, there is a valid
connection.
down
The interface is down, data transfer is not possible. In other words, there is no valid
connection. For example, because the onboard G703 is not connected.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/ais
This attribute indicates (on / off) whether an alarm indication signal has been received on the interface.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/los
This attribute indicates (on / off) whether a loss of signal has occurred.
crocusIfConvNx64<Tt/Cv>/g703OnBoard/lfa
This attribute indicates (on / off) whether a loss of frame alignment has occurred. This attribute is only
present on the Crocus Nx64 CNV.
Reference manual
Description
Status attributes
103

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Crocus CNV and is the answer not in the manual?

Table of Contents