Changing the Cutting Unit's Belt

!
WARNING!
Protect your hands with gloves when working with the blades.
There is a risk of crush injuries when working with the belt.
Belt changes on the Combi unit.
On these cutting units with "collision-proof"
blades, the blades are driven by one V-belt.
Do as follows to change the V-belt:
1.
Remove the cutting unit, see page 43.
2.
Loosen the unit frame (1) see page 45,
the bolt to the parallelism handle (2), and
the two screws on the cover (3). Lift the
protective cover from the belts.
3.
Loosen the spring (4) that tensions the
V-belt and wriggle the belt off.
4.
Attach the new belt.
The belt tightening schedule is located
on a decal on the inside of the protective
cover.
5.
Check that the belt tensioning equipment
is not jammed or binding and replace the
spring.
6.
Replace the protective cover and attach
the parallelism handle and unit frame.
7.
Attach the cutting unit to the machine, see Attaching the Cutting Unit on page 38.

Removing the BioClip Plug (Combi)

To change a Combi unit from the BioClip
function to a cutting unit with rear ejection,
remove the BioClip plug, which is located
under the unit, attached with three screws.
1.
Put the unit in service position, see The
Cutting Unit's Service Position on
page 41.
2.
Remove the three screws holding the
BioClip plug, and remove the plug.
3.
Tip: Fit three full-thread screws M8x15
mm in the screw holes to protect the
threads.
4.
Return the unit to the normal position.
Fit the BioClip plug in the reverse order.