Main Fuse

The fuse is placed in a detachable holder
under the battery case's lid, in front of the
battery.
Type: Flat pin, 15 A
Do not use any other type of fuse when
changing.
A blown fuse needs to be replaced. Pull the
fuse from the holder when changing.
The fuse is there to protect the electrical
system. If it blows again shortly after the
change, it is due to a short circuit, which must
be remedied before the machine can be put
into operation again.

Checking the Safety System

The Rider is equipped with a safety system that prevents starting or driving under the following conditions.
The engine should only be possible to start when the cutting unit is in its raised position and the hydrostat
pedals are in the neutral position.
The driver does not need to be seated in the driver's seat.
Make daily inspections to ensure that the safety system works by attempting to start the engine when one
of the conditions is not met. Change the conditions and try again.
Check that the engine stops if you temporarily move out of the driver's seat while the cutting unit is lowered
or the hydrostat pedals are not in the neutral position.