connected to the WIM using one of the 2 methods described in the previous section
Section 3.3.10).
PLEASE NOTE:
The PLIM/PLIM2 module uses the -48V rail from the OS7200 power supply to provide power
to connected devices over Ethernet. The OS7200 power supply provides up to 2200mA of
output current. PER EACH OS7200 CABINET (not per system), the SUM of all current
drawn from 1) devices powered by PLIM cards, 2) digital key sets connected to DLI ports
3) analog devices connected to SLI ports and 4) COMBO WBS24 AP's connected to 4WLI
cards cannot exceed 2200mA. The chart below provides current ratings for various devices
connected to the system:
Card Name
DLI
Digital Keyset
Analog Phone
MWSLI
Analog Phone with Message Waiting
Lamp
ITP-5121D or ITP-5107S
ITP-5112L
SMT-R2000 Dual AP
SMT-i3105
PLIM/PLIM2
SMT-i5210
(48 V)
SMT-i5220, SMT-i5230
SMT-i5243
SMT-i5264
A52GE Gigabit
Other IEEE 802.3af compliant device.
IF ADDING PLIM/PLIM2 CONNECTED DEVICES CAUSES THE TOTAL CURRENT DRAWN TO
EXCEED 2200mA PER CABINET (not per system), THEN YOU MUST CONNECT THE OS7150
EXTERNAL PoE POWER SUPPLY MODULE to the cabinet. This unit will provide additional
power only to devices connected to PLIM/PLIM2s, when the OS7200 power supply limits have
been exceeded. Please refer to
SUPPLEMENTAL POWER SUPPLY for further information.
Refer to the OfficeServ 7200 Data Server Manual for detailed PLIM installation and
configuration information.
It is important to note that the OS7150 only provides additional power to the PLIM/PLIM2.
The OS7150 is used when the PLIM/PLIM2 connected devices causes the total current draw
per cabinet to exceed 2200mA. It does not provide power to DLI, MWSLI and 4WLI ports.
Connected
Device Type
Section 5.3, CONNECTING THE OS7150 EXTERNAL PoE PSU
3.35
Home Page
PART 3 MAY 2010
Current Consumption
per Each Device (mA)
25
25
30
100
130
200
83
127
107
156
100
56
See manufacture current draw specifications