Figure 3.3B Mp20 Switch Settings - Samsung OfficeServ 7200 Technical Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

OfficeServ 7200
TECHNICAL MANUAL
3.2.2 Setting Switches on the MP20
The MP20 processor card does not have a memory backup switch because it uses volatile
NAND flash memory to store the database.
MP20 and use of the RESET
3.3b, MP20 Switch Settings) used to customize the user requirements and system
configuration at start up. The description of each setting is described below.
ON (left)
4 DIGIT STATION NUMBERS
4 DIGIT STATION GROUPS
4 DIGIT TRUNK NUMBERS
See Section 9.2.2, Database Management on the
button. There is a set of dip switches designated as S3 (see Figure

Figure 3.3b MP20 Switch Settings

DIP SWITCH USE (S3)
SW8
SW7
SW6
RESERVED
SW5
COUNTRY SELECT
SW4
COUNTRY SELECT
SW3
COUNTRY SELECT
SW2
COUNTRY SELECT
SW1
3.5
Home Page
OFF (right)
3 DIGIT STATION NUMBERS
3 DIGIT STATION GROUPS
3 DIGIT TRUNK NUMBERS
RESERVED
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT
COUNTRY SELECT
Table of Contents
INSTALLATION
PART 3 MAY 2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents