Appendix D --- Error codes
100-50259
Firmware unable to identify SUI-board id.
Try the following:
Check Scanner Controller ID switch
Reload Firmware
100-50260
Firmware unable to identify SUI-board variant.
Try the following:
Check Scanner Controller ID switch
Reload Firmware
100-50261
Scanner is locked
Try the following:
Reboot system
100-50300
Unable to set scanner model
Try the following:
Check Scanner Controller ID switch
Reload Firmware
100-50303
Scanner has no serial number.
Try the following:
Run SCANtest, test 1 See Appendix A
100-50505
SUx. FRAM Error.
Try the following:
Download new firmware.
Scanner Controller Board SUI
100-60083
IMx, wrong board version installed
Try the following:
Replace the Interface board IMx.