Appendix A
Provides you with a live image of
what the CIS elements are looking at.
"Light Profile"
Uncorrected light profile shows the
raw data from the CIS module
Corrected light profile shows the cali-
brated data.
See note about dpi, B-5.
Test 11. Stitching & Vertical Align.
Allow you to adjust either Alignment
or Stitching between 2 CIS modules.
1) Select Alignement or Stitching
2) Select the transition area
3) Use the arrows to either increase or
If the DPI is changed it requires a
rescan. See note, B-5.
Alignment have to be correct before
Stitching can be adjusted!
Under normal circumstances Align-
ment and Stitching will be adjusted
automatically by running SM
Test 6. Motor Test
Here the motor can be tested at vari-
ous speed and directions.
This Test can be useful if there is
banding in scan width or complains
about noise while scanning!
Test 9. Camera Adjustment