VCC Voltage at the Common Collector (positive [+] electrical connection)
VTT Voltage Termination
SUL Test Points
TP1
Main
TP2
VCC
TP3
VCC
TP6
VCC
TP7
VCC
TP8
VCC
TP15
VTT
Measured to ground J8, pin 3

Design MG52D

Value
5 V ± 5%
5 V ± 5%
12 V ± 5%
2.5 V ± 5%
1.8 V ± 5%
3.3 V ± 5%
0.9 V ± 5%