Stepper Motor Assy - Contex XD2490 Service Manual

Contex xd2490
Hide thumbs Also See for XD2490:
Table of Contents

Advertisement

Stepper Motor Assy.

*Switch Scanner off and disconnect from power source and PC prior to any repair.
Remove RHS cover, see page 4-5
Part replacement MG52D
1. Lift up connector lock.
2. Pull out USB connector and cable.
Replace USB cable and reverse steps.
1. Loosen screw.
2. Release tension on belt by lifting upward
3. Disconnect cable.
4. Remove screws and motor.
1. Remove screws.
2. Remove motor mount.
Install the new Motor and reverse the steps.
Adjust Belt tension, see page 4-8.
and tighten nut again.