There are 8 program parameter groups:
Overview of the individual program parameters
94
Symbol
Parameter group
PP1 - Configuration
General settings
PP2 - Insertion mode
Insertion mode and position
PP3 - Removal mode
Removal mode and position
PP4 - Softstart
Number of stitches and speed
PP5 - Needle thread monitor
Sensitivity value for the needle thread monitor
PP6 - Thread consumption
Values for determining thread consumption
PP7 - Offset
Contour is offset in a particular direction
PP8 - Scaling:
The size of the contour is changed.
PP1 - Configuration
Symbol
Meaning
Seam name
max. 20 characters
Minimum sewing foot stroke height
(min. = 1.0 .. max. = 10.0; Def. = 5.0 mm )
Sets this as the minimum value of the programmable sewing foot stroke
height so that only this value needs to be adjusted when sewing thicker
materials.
Adjust the thread tension
(min. = 10 .. max. = 200; Def. = 100 %)
The thread tension profile for the entire contour is adjusted accordingly.
A value of 100 % means that no adjustments are made.
Adjust the run-empty speed
(min. = 10 .. max. = 200; Def. = 100 %)
The forwarding speeds are adjusted accordingly.
Clamp ID code
Barcode (ID code) of max. 10 characters for performing a safety check
before the start of sewing (the barcode reader additional equipment must
be activated)
Laser marking lights
Up to four laser marking lights for easier alignment of the sewing material
can be controlled (the additional equipment must be activated)
Settings via the software
Operating instructions 906 - Version 00.0 - 05/2014