Settings via the software
Testing inputs and outputs
This manual only provides an overview of the test possibilities.
The tests may only be performed by qualified personnel that have
received training from Dürkopp Adler.
1. In the Extras > Service > Multitest menu item, tap the test
 The IO Test Page window is displayed.
Figure 72: Testing inputs and outputs
(1) - Area for input elements
The input elements are listed and selected at the left side (1) and the out-
put elements at the right side (2).
2. Use Select + or Select - to select the desired element in the
 The number of the element is displayed on the Selected: button.
3. Tap the Selected: button.
4. Test the element using the On/Off or Switchover buttons, depending
Operating instructions 906 - Version 00.0 - 05/2014
WARNING
Risk of injury from sharp or moving parts.
Do reach into the machine during function testing of
the input or output elements.
Inputs/outputs option.
respective area.
on the type of the input or output element.
(2) - Area for output elements
109