Settings via the software
MP6 - Counters
Symbol
Meaning
Counter type
The following options are available:
Piece counter increments (Def.)
The counter is incremented after each sewn program.
Piece counter decrements
The counter is decremented after each sewn program.
Sequence counter increments
The counter is incremented after each sewn sequence.
Sequence counter decrements
The counter is decremented after each sewn sequence.
Reset value for the counters
(min. = 0 .. max. 9999; Def. = 0)
Value to which the counter is set when a counter reset is performed.
Seam counting for bobbin supply
(min. = 0 .. max. = 100; Def. = 0)
A message is displayed to the user after the number of seams specified
here have been sewn. A value of 0 deactivates the function.
Bobbin supply capacity
(min. = 0.0 .. max. = 400.0; Def. = 0.0 m )
A message is displayed to the user after the bobbin supply capacity has
been consumed. A value of 0 deactivates the function.
104
Operating instructions 906 - Version 00.0 - 05/2014