5. Make sure that bottom paper guide can move up and down freely. Ensure that the
gaps pointed by the arrows are equal and measures approximately ½ a millimeter
(20 mils or the thickness of 5 sheets of TITO paper). If not, readjust the frame to
ensure proper alignment.
Document # 720006-0000
August, 2011
Figure 28: Bottom paper guide inspection
Service Manual