TOP COVER SENSOR (TCS)

1. Remove the PANEL COVER. (See page 5-8)
2. Remove two TCS BRACKET mounting screws, and then remove the TCS BRACKET and the TCS
FEELER. Disconnect the connector of the TCS.

CONTACT GLASS

1. Open the scanner cover.
2. Slide the Glass Holder to remove the contact glass.
2. Slide the CONTACT GLASS to remove it.