5. Turn the power on and then press SW1 on the board.
"0" will be indicated on the left ROM NO. and "1" will be on the right ROM NO.
Dots will be lighted on the CHECK SUMs.
6. The Flash ROM writer erases the current program in the machine, then starts writing the new program to
the machine.
Note: The CGROM0 is indicated as "4" and the CGROM1 is "5".
7. At the end of this operation (it takes a few minutes), the Flash ROM writer indicates the Check Sums of the
last ROMs.
8. Pressing the SW1, confirm the Check Sums as follows:
Check Sum of ROM0, Check Sum of ROM1
Check Sum of ROM2, Check Sum of ROM3
Check Sum of ROM4(CGROM0), Check Sum of ROM5(CGROM1)
If the Check Sum indicated on the Flash ROM writer and the one written on the ROM are not same,
confirm that the cable connection and the ROM placement, then perform from step 1 again.
9. Turn off the power switch, then disconnect the cables.
10. Re-attach the Access cover.

Error code

If the error occurred during writing, the following error code will be appeared:
E.02: Maker code read error
E.04: Sector erase error
E.05: Writing error
E.06: Sum check error
E.07: Time out error
When the above errors occur, turn off the power switch, confirm the cable connection and the ROM
placement, and then perform from step 1 again.
(Pressing SW1)
(Pressing SW1)
3-130
(Pressing SW1)