Vent Confi Gurations - Valor Retrofire RF24IDN Installation And Owner's Manual

Valor retrofire direct vent fireplace insert
Hide thumbs Also See for Retrofire RF24IDN:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Allowable Vent Confi gurations
The RF24 is certifi ed for use with approved 3" diameter
fl exible venting installed into an approved existing solid
fuel burning masonry or factory built chimney system.
The venting system must terminate vertically at the
roof using an approved termination cap. Both inlet and
exhaust liners must be run continuously from appliance
to roof termination.
10"
10"
3" Inlet & Exhaust
Collars (exhaust collar
is slighthly longer)
559CLT
Termination
18
Vent Confi gurations
559CLT
Co-Linear Terminal
See
Chart
Where possible, avoid joints in fl ex pipe. If joints
are required, use only connectors approved by the
manufacturer of the fl ex pipe. Field fabricated joints
are not allowed.
Any generic 3" diameter fl exible venting approved
for venting gas appliances is acceptable. See list of
the approved venting components on page 32 of this
manual.
40'
35'
30'
25'
20'
15'
10'
Allowable Horizontal Offset
!
Failure to position the parts in
Failure to position the parts in
accordance with these diagrams or
accordance with these diagrams or
failure to use only parts specifi cally
failure to use only parts specifi cally
approved with this appliance
approved with this appliance
may result in property damage or
may result in property damage or
personal injury.
personal injury.
3" Liners
3" min. Bend
Radius
WARNING

Advertisement

Table of Contents
loading

This manual is also suitable for:

Retrofire rf24idp

Table of Contents