Panasonic DBS 40 Manual page 74

Digital business system
Hide thumbs Also See for DBS 40:
Table of Contents

Advertisement

Section 300~Installation
Installing
1.
2.
3.
4.
6.
7.
8.
DBS-70-300
a Double Cabinet with Tls in the Master and
in
Install the Sync Unit in the master cabinet as described in Steps 1 and 2
under "Installation for a Single Tl."
Install a Tl MDF card in each cabinet. (See Step 3 on page 4-23.)
Set Switch 1 on the Tl cards. (See Step 4 on page 4-24.)
Install a Tl card in each "EC/TRK" slot.
Connect the Clock Sync Cable from CN4 on the master-cabinet Tl to
Note:
Part Number VB-43564 is used for the Clock Sync Cable when Tls
are installed in the master and slave cabinets.
At the master cabinet, connect the Sync Cable from CNl on the Sync
Unit to CN5 on the Tl card (Figure 4-12).
At each cabinet, connect the cable attached to CN3 on the Tl MDF card
to CN3 on the Tl card (Figure 4-10).
Using an RJ48 cable, connect CNl of each Tl MDF card to a CSU. (See
Figure 4-9 on page 4-25 for RJ48 pinouts.)
For both cabinets, connect the ground cable from the Tl MDF card as
shown in Figure 4-10 on page 4-26.
Chapter 4. Trunks and Lines
Slave
4-29