3 Functions of NB-Designer
Then place the component in the window.
Now the recipe data transmission component is created, but it can only specify to transfer the 5 words
beginning from address of 4X200 to the recipe memory instead of the specific position of the recipe
memory. The words reserved by the system can handle this situation easily. Set the LW9000 to 300 and
press the transmission component button, then the 5 words beginning from 4X200 will be transferred to
the 5-word addresses after the start address of RW300. If you want to transfer the 5 words beginning
from the address of 4X200 to RW100 again, then you just need to set LW9000 to 100, and then press
the transmission component button to complete the data transmission.
Let's finish this example. Place 3 Text Input components to modify/display the data.
(1) 4X200: Addr. Type of 4X, Address of 200 and Word Length of 5.
(2) RWI0: Addr. Type of RWI, Address of 0 and Word Length of 5.
(3) RW300: Addr. Type of RW, Address of 300 and Word Length of 5.
Then create one Number Input component to modify the data of LW9000 with the Addr. Type of LW and
Address of 9000.