Addresses
9210
Display values of each channel of
browsing points
9260~9261
Start address for RW clearing operation
9262~9263
Word length of RW clearing operation
9264~9279
Mask code of PLC Station No.(COM 2)
9296~9299
Mask code of error information
9370
Operator Confirm method
9380~9395
History value of Number Input
component
9416~9431
Index Register for Station No. variable
9432~9447
Register for indicating communication
state (COM 2)
9465
Time-out ratio of Macro
9486~9501
User name
9502~9503
User password
9504~9505
Current authority
9506~9507
Authority setting
9508~9509
Automatic Login Out Time setting
9510~9511
Password Confirm
9520~9521
Curser position
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
Descriptions
3 Functions of NB-Designer
Comments
The current value of each channel is displayed one by
one according to the bit width of the browsed Trend
Curve.
Sets the start address for RW clearing operation
triggered by LB9130.
Sets the word length for RW clearing operation
triggered by LB9130.
Each bit corresponds to one Station No. of COM 2 (i.e.
9264.0 corresponds to Station No. 0... and 9279.F
corresponds to Station No. 255). When the bit is turned
ON, the communication corresponding to Station No.
will be masked (read/write).
Each bit corresponds to one piece of error information.
When the bit is turned ON, the corresponding prompt
error information will be masked. e.g. "PLC No
Response" is 9296.2 (read/write).
Operator Confirm method:
1: Confirm; 2: Cancel (write).
Displays the data of Number Input component before
the input operation (read).
Each word corresponds to the index (0~15) for Station
No. variable.
Each bit corresponds to one Station No. (9432.0
...
corresponds to 0,
, and 9447.F corresponds to 255).
The relevant bit is set to ON when PLC is under time-
out condition and has no response, otherwise it will be
set to OFF.
The single allowed maximum operation time of Macro
is N times the default value when the LW is set to ON
(read/write).
Inputs the login user name of up to 32 characters
(read/write).
Inputs the password corresponding to the login user
(read/write).
Displays 32 authorities corresponding to current login
users (read).
Double-words and 32 authorities' assignments.
LW9506 to LW9507 corresponds to 32 authorities (No.
0 to No. 31) and LW.B corresponds to each bit in
LW9506 to LW9507. For example: LW.B 9506.0
represents the authority of No. 0; and LW.B 9506.A
represents the authority of No. 10 (write).
Sets the unit of automatic login out time to minute
during the addition of user information (write).
Inputs the password again for consistency confirmation
during the addition of user information (write).
Refers to the curser position (X
(read).
,
Y) in input component
3-317
3