Omron NB Series Operation Manual page 257

Nb-series programmable terminals
Hide thumbs Also See for NB Series:
Table of Contents

Advertisement

3 Functions of NB-Designer
Process of adding Data Transmission
1
Drag the Data Transmission icon to the window after it being pressed, then the [Data
Transmission Component Attribute] dialog box will pop up.
Data Type: Includes Bit and Word transmission.
Data Length: The number of data transferred by the Data Transmission component. When the
data type is Bit or Word, the units are "bit" or "word" respectively.
Source Address: Sets the source address of the transferred data.
Destination Address: Sets the destination address of the data transmission.
Variable Parameter: Sets the offsets of the source address, destination address and data
length read from the specified register.
Take the following graphics as example, i.e. the source address, destination address and data
length use the variable parameters.
After setting the source address type to "D register" and making the source address offset
controlled by the variable LW100, set the destination address type to "LW register" and make
the destination address offset and the data length controlled by the variable LW101 and LW102
respectively.
3-216
NB-series Programmable Terminals NB-Designer Operation Manual(V106)

Hide quick links: