Install the memory board.
8.
Install the processor air baffle.
9.
Install the access panel (on page 26).
10.
Do one of the following:
11.
Close or install the tower bezel, as needed.
o
Slide the server back into the rack.
o
Power up the server.
12.
Configure the memory.
13.
FBDIMM installation guidelines
Always observe the following guidelines when installing additional memory:
•
Always install memory in pairs of equal capacity.
•
Install FBDIMMs into both slots within a single bank.
•
Always install memory in pairs in sequential bank order, starting with bank A.
•
Install supported DDR2 FBDIMMs.
•
For maximum performance, install a minimum of four FBDIMMs across both memory boards (two
FBDIMMs per board).
For online spare and mirrored memory support, always observe additional guidelines
memory" on page 44).
Removing FBDIMMs
To remove the component:
Power down the server (on page 20).
1.
Do one of the following:
2.
Open or remove the tower bezel, as needed
o
Extend the server from the rack (on page 22).
o
("Open or remove the tower
Hardware options installation 48
("Online spare
bezel" on page 21).