Specifications
Server specifications
Specification
Dimensions
Rack model
Height
Depth
Width
Tower model
Height
Depth
Width
Weight
Weight (maximum)
Weight (when lightly loaded)
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
* 100 to 127 VAC is required for 10 A; 200 to 240 VAC is required for 6.7 A.
Environmental specifications
Specification
Temperature range*
Operating
Shipping
Maximum wet bulb temperature
Value
—
21.92 cm (8.63 in)
65.41 cm (26.5 in)
44.45 cm (17.50 in)
—
47 cm (18.5 in)
71.1 cm (28 in)
21.92 cm (8.63 in)
40.8 kg (110 lb)
24.9 kg (55 lb)
100 VAC to 240 VAC *
47 Hz to 63 Hz
10 A (100 V) to 6.7 A (200 V)
1500 W
2730
800 W (low line), 1000 W (high line)
1000 W (low line), 1200 W (high line)
Value
10°C to 35°C (50°F to 95°F)
-40°C to 70°C (-40°F to 158°F)
28°C (82.4°F)
Specifications 119