Parameter
Name
Second motor
458
constant (R1)
Second motor
459
constant (R2)
Second motor
460
constant (L1)
Second motor
461
constant (L2)
Second motor
462
constant (X)
Second motor auto
463
tuning setting/status
Tuning data unit
684
switchover
Torque current
859
Second motor
860
torque current
89
Refer to Pr. 81.
90 to 94
Refer to Pr. 82 to Pr. 84.
Incre-
Initial
Range
ments
Value
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 50Ω/
is automatically set.)
0.001Ω/
0 to 400mΩ *
* The increments and setting range differ
9999
0.01mΩ *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 50Ω/
is automatically set.)
0.001Ω/
0 to 400mΩ *
* The increments and setting range differ
9999
0.01mΩ *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Tuning data of the second motor
0 to 50Ω (0 to
(The value measured by offline auto tuning
0.001Ω
1000mH)/
is automatically set.)
(0.1mH)/
0 to 3600mΩ
* The increments and setting range differ
9999
0.01mΩ
(0 to 400mH) *
(0.01mH) *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Tuning data of the second motor
0 to 50Ω (0 to
(The value measured by offline auto tuning
0.001Ω
1000mH)/
is automatically set.)
(0.1mH)
0 to 3600mΩ
* The increments and setting range differ
9999
/0.01mΩ
(0 to 400mH) *
(0.01mH) *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Tuning data of the second motor
0 to 500Ω
(The value measured by offline auto tuning
0.01Ω
(0 to 100%)/
is automatically set.)
(0.1%)/
0 to 100Ω
* The increments and setting range differ
9999
0.01mΩ
(0 to 100%) *
(0.01%) *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Set the tuning mode of the second motor.
1
0
0, 1, 101
(same as Pr. 96)
0
Internal data converter value
1
0
Displayed in "A, Ω, mH, %".
1
Tuning data
(The value measured by offline auto tuning
0 to 500/
is automatically set.)
0.01/
0 to 3600A *
* The increments and setting range differ
9999
0.1A *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Tuning data of the second motor
(The value measured by offline auto tuning
0 to 500/
is automatically set.)
0.01/
0 to 3600A *
* The increments and setting range differ
9999
0.1A *
Use the Mitsubishi motor (SF-JR, SF-
9999
HRCA, etc.) constants
Description
according to the inverter capacity. (55K or
lower/75k or higher)
according to the inverter capacity. (55K or
lower/75k or higher)
according to the inverter capacity. (55K or
lower/75k or higher)
according to the inverter capacity. (55K or
lower/75k or higher)
according to the inverter capacity. (55K or
lower/75k or higher)
according to the inverter capacity. (55K or
lower/75k or higher)
according to the inverter capacity. (55K or
lower/75k or higher)