(3) Alarm
When an alarm occurs, the output is not shut off. You can also output an alarm signal by making parameter setting. (Set
"98" in any of Pr. 190 to Pr. 196 (output terminal function selection). (Refer to Chapter 4 of
Operation Panel
Indication
Name
Fan alarm
For the inverter that contains a cooling fan,
Description
stops due to a fault or different operation from the setting of Pr. 244 Cooling fan operation selection.
Check point
Check the cooling fan for a fault.
Corrective action
Check for fan fault. Please contact your sales representative.
(4) Fault
When a fault occurs, the inverter trips and a fault signal is output.
Operation Panel
Indication
Name
Overcurrent trip during acceleration
When the inverter output current reaches or exceeds approximately 220% of the rated current during
Description
acceleration, the protective circuit is activated to stop the inverter output.
· Check for sudden acceleration.
· Check that the downward acceleration time is not long in vertical lift application.
· Check for output short circuit.
· Check that the Pr. 3 Base frequency setting is not 60Hz when the motor rated frequency is 50Hz.
· Check if the stall prevention operation level is set too high. Check if the fast-response current limit
Check point
· Check that the regeneration is not performed frequently. (Check that the output voltage becomes larger
· Check that the power supply for RS-485 terminal is not shorted. (under vector control)
· Check that the rotation direction is not switched from forward to reverse rotation (or from reverse to
· Increase the acceleration time.
· When "E.OC1" is always lit at starting, disconnect the motor once and start the inverter.
· Check the wiring to make sure that output short circuit does not occur.
· Set the Pr. 3 Base frequency to 50Hz. (Refer to page 58.)
· Lower the setting of stall prevention operation level. Activate the fast-response current limit operation.(Refer
Corrective action
· Set base voltage (rated voltage of the motor, etc.) in Pr. 19 Base frequency voltage. (Refer to Chapter 4 of
· Check RS-485 terminal connection. (under vector control)
· Prevent the motor from switching the rotation direction from forward to reverse (or from reverse to
Operation Panel
Indication
Name
Overcurrent trip during constant speed
When the inverter output current reaches or exceeds approximately 220% of the rated current during
Description
constant speed operation, the protective circuit is activated to stop the inverter output.
· Check for sudden load change.
· Check for output short circuit.
· Check if the stall prevention operation level is set too high. Check if the fast-response current limit
Check point
· Check that the power supply for RS-485 terminal is not shorted. (under vector control)
· Check that the rotation direction is not switched from forward to reverse rotation (or from reverse to
· Keep load stable.
· Check the wiring to make sure that output short circuit does not occur.
· Lower the setting of stall prevention operation level. Activate the fast-response current limit operation.(Refer
Corrective action
· Check RS-485 terminal connection. (under vector control)
· Prevent the motor from switching the rotation direction from forward to reverse (or from reverse to
FN
E.OC1
operation is disabled.
than the V/F reference voltage at regeneration and overcurrent occurs due to the high voltage.)
forward) during torque control under Real sensorless vector control.
(Shorten the downward acceleration time in vertical lift application.)
If "E.OC1" is still lit, contact your sales representative.
to Chapter 4 of
the Instruction Manual (Applied).)
the Instruction Manual (Applied).)
forward) during torque control under Real sensorless vector control.
E.OC2
operation is disabled.
forward) during torque control under Real sensorless vector control.
to Chapter 4 of
the Instruction Manual (Applied).)
forward) during torque control under Real sensorless vector control.
Causes and corrective actions
the Instruction Manual (Applied).))
FR-PU04
FN
FR-PU07
appears on the operation panel when the cooling fan
FR-PU04
OC During Acc
FR-PU07
FR-PU04
Stedy Spd OC
FR-PU07
4
143

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents