Mitsubishi Electric FR-A720-0.4K Instruction Manual page 12

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

400V class
Motor Output
Applicable Inverter Model
(kW)
0.4
FR-A740-0.4K
0.75
FR-A740-0.75K
1.5
FR-A740-1.5K
2.2
FR-A740-2.2K
3.7
FR-A740-3.7K
5.5
FR-A740-5.5K
7.5
FR-A740-7.5K
11
FR-A740-11K
15
FR-A740-15K
18.5
FR-A740-18.5K
22
FR-A740-22K
30
FR-A740-30K
37
FR-A740-37K
45
FR-A740-45K
55
FR-A740-55K
75
FR-A740-75K
90
FR-A740-90K
110
FR-A740-110K
132
FR-A740-132K
160
FR-A740-160K
185
FR-A740-185K
220
FR-A740-220K
250
FR-A740-250K
280
FR-A740-280K
315
FR-A740-315K
355
FR-A740-355K
400
FR-A740-400K
450
FR-A740-450K
500
FR-A740-500K
*1
Select the MCCB according to the power supply capacity. Install one MCCB per inverter.
For installation in the United States, Class RK5, Class J, Class CC, Class L, Class T or any faster acting fuses
or UL 489 Molded Case Circuit Breaker (MCCB) must be provided, in accordance with the National Electrical
Code and any applicable local codes.
For installation in Canada, Class RK5, Class J, Class CC, Class L, Class T or any faster acting fuses or UL
489 Molded Case Circuit Breaker (MCCB) must be provided, in accordance with the Canada Electrical Code
and any applicable provincial codes. (Refer to page 193.)
*2
Magnetic contactor is selected based on the AC-1 class. The electrical durability of magnetic contactor is 500,000 times. When the magnetic
contactor is used for emergency stop during motor driving, the electrical durability is 25 times.
When using the MC for emergency stop during motor driving or using on the motor side during commercial-power supply operation, select the MC
with class AC-3 rated current for the motor rated current.
CAUTION
⋅ When the inverter capacity is larger than the motor capacity, select an MCCB and a magnetic contactor according to the
inverter model and cable and reactor according to the motor output.
⋅ When the breaker on the inverter primary side trips, check for the wiring fault (short circuit), damage to internal parts of the
inverter, etc. Identify the cause of the trip, then remove the cause and power on the breaker.
REMARKS
Motor Output (kW) in the above table indicates values when using the Mitsubishi 4-pole standard motor with power supply
voltage of 400VAC 50Hz.
Moulded Case Circuit Breaker
(MCCB)
or Earth Leakage
*1
Circuit Breaker (ELB)
(NF or NV type)
Power factor improving
(AC or DC) reactor
without
with
5A
5A
5A
5A
10A
10A
10A
10A
20A
15A
30A
20A
30A
30A
50A
40A
60A
50A
75A
60A
100A
75A
125A
100A
150A
125A
175A
150A
200A
175A
225A
225A
225A
400A
400A
400A
500A
600A
600A
700A
800A
900A
1000A
1200A
Peripheral devices
Input Side Magnetic Contactor
Power factor improving
(AC or DC) reactor
without
with
S-N10
S-N10
S-N10
S-N10
S-N10
S-N10
S-N10
S-N10
S-N10
S-N10
S-N20, S-N21
S-N11, S-N12
S-N20, S-N21
S-N20, S-N21
S-N20, S-N21
S-N20, S-N21
S-N25
S-N20, S-N21
S-N25
S-N25
S-N35
S-N25
S-N50
S-N50
S-N65
S-N50
S-N80
S-N65
S-N80
S-N80
S-N95
S-N150
S-N180
S-N220
S-N300
S-N300
S-N400
S-N600
S-N600
S-N600
S-N600
S-N800
1000A
Rated product
1000A
Rated product
MCCB
INV
MCCB
INV
*2
2
IM
IM
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents