OPTIMOD PC
Only one valid command is permitted per line.
The 1101 will not respond to unrecognized commands.
The character code supported is ASCII.
Connecting via TCP/IP Using a Terminal Program on a PC
You can use the 1101 with any computer or terminal that is compatible with
TCP/IP networking.
The Optimod-PC Service Settings determine network connection security:
A) Using the Optimod-PC Control Application, select T
B) Assign an available TCP/IP Port. (Default is 11101.)
C) Uncheck "Use localhost only for Terminal Access."
D) (Optional) Check "Use Network Accept List" and add allowed IP addresses to
list.
Connect your computer or terminal with an Ethernet cable:
A) Connect an appropriate Ethernet cable on your terminal, computer, or device
to either an Ethernet port on the 1101's host computer or the Ethernet net-
work that will allow access the 1101 host computer.
• If connecting to a standard Ethernet network, use a standard Ethernet ca-
ble and TCP/IP network connection.
> S
S
OOLS
ERVICE
ETTINGS
6-11
CONTROL API
.