6-8
CONTROL API
Connecting via Serial Port Using a Terminal Program on a PC
and change settings on the 1101 by using simple ASCII commands, as discussed in
Optimod-PC System/Mixer Control API starting on page 6-1.
•
Valid commands are in either upper or lower case, not a combination.
•
Only one valid command is permitted per line.
•
The 1101 will not respond to unrecognized commands.
•
The character code supported is ASCII.
•
The 1101 can be used with any computer or terminal that is compatible with the
RS-232 standard interface.
•
The serial port is configured via the Optimod-PC Service Settings:
A) Using the Optimod-PC Control Application, select Tools > Service Settings.
B) Check "Allow Serial Port Access."
C) Select Configuration for Serial Port Settings, and configure the desired Serial
port and parameters.
•
Users will connect their computer or terminal with a null modem cable. Refer to
the GPIO device documentation to determine which type of serial cable is re-
quired to connect to a PC, if used. Only direct serial connections are supported;
there is no provision for communications via modem.
•
Communications configuration is 115200, N, 8, 1, no handshaking
ORBAN MODEL 1101